Pos: 105 /Lampen/Wasserspieltechnik/Water Jet Lightning/Batteriewechsel Handsender Water-Jet-Lightning @ 8\mod_1221040331102_121.doc @ 52369
Battery change in the manual transmitter (Q, R)
Improper treatment can lead to damage of the manual transmitter!
− Touch an uncoated metal surface (e.g. radiator) to discharge static charges that could lead to damage to
the internal components of the manual transmitter!
− Prevent the ingress of dirt and humidity into the manual transmitter!
− Insert a screwdriver (43) into the lateral opening (44) of the manual transmitter.
− Open the housing of the manual transmitter by slightly turning the screwdriver, then remove the housing bottom
section (45).
− Pull the battery (46) out of the holder (47).
− Push the new battery (type CR 2032) into the holder (47). Ensure that the embossed side (48) of the battery points
upward.
Pos: 106 /Alle Produkte/Dummy_module/Abstand 6 pt @ 7\mod_1196627997106_0.doc @ 41651
Pos: 107 /Alle Produkte/Überschriften/H1 Lagern / Überwintern @ 7\mod_1196625251745_121.doc @ 41495
Storage/Over-wintering
Pos: 108 /Lampen/Wasserspieltechnik/Water Jet Lightning/Lagern und Überwintern Water Jet Lightning @ 8\mod_1221564068782_121.doc @ 52503
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Store the Water Jet Lightning frost-free, store the pump frost-free and immersed in a container filled with wa-
ter (Figure S). Do not immerse the plug.
Pos: 109 /Alle Produkte/Dummy_module/Abstand 6 pt @ 7\mod_1196627997106_0.doc @ 41651
Pos: 110 /Alle Produkte/Überschriften/H1 Entsorgung @ 7\mod_1196625583904_121.doc @ 41547
Disposal
Pos: 111 /Alle Produkte/Entsorgung - gem. Bestimmungen @ 8\mod_1223247321369_121.doc @ 53910
Dispose of the unit in accordance with the national legal regulations.
Pos: 112 /Alle Produkte/Dummy_module/Abstand 6 pt @ 7\mod_1196627997106_0.doc @ 41651
Pos: 113 /Alle Produkte/Überschriften/H1 Störungsbeseitigung @ 7\mod_1196625290699_121.doc @ 41521

Remedy of faults

Pos: 114 /Lampen/Wasserspieltechnik/Water Jet Lightning/Störungstabelle Water Jet Lightning @ 8\mod_1223307429894_121.doc @ 53993
Malfunction
The pump does not switch on
LED not lit
Insufficient fountain height
Pos: 115 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1630
Cause
No mains voltage
Remote control not taught in
Both sockets at the 12V control box must be
occupied
Impeller blocked or soiled
Pump strainer casing soiled
Nozzles soiled
Foam filters soiled
Hose kinked
Y distributor clogged
Valves at the Y distributor closed
Y distributor incorrectly adjusted
Remedy
Check mains voltage
Check supply lines
Teach-in the remote control
− Insert the plugs of both Water Jet Lightning
units in the sockets
− If only one Water Jet Lightning is operated,
plug the jumper into the second socket
Clean impeller
Clean strainer casing
Clean nozzles
Wash out foam filters
Lay hose in a sufficiently large bend
Open valves and clean Y distributor
Open valves
Uniformly adjust Y distributor