Press the ↵ key for about 4 seconds to confirm. The display counts down to "AF00".
•
The last calibration value is displayed.
Press the ▲ key to leave the calibration mode, the weigh systems displays eg. AP 11
•
(internal value).
Press the ↵ key for about 4 seconds, the system returns to standard weighing mode,
•
shows the actual weight on the forks, the calibration is completed and the calibrati-
on load can be lowered.
10.2. MULTI-POINT CALIBRATION
The weighing system should be turned on and the zero calibration should already be
completed.
Press the ▼ key for 20 seconds. The indicator shows the value of the first calibrati-
•
on point, the NET pointer is flashing. Use the ▼, ▲and ↵ keys to enter the correct
calibration weight.
Press the ↵ key shortly, the right segment starts flashing.
•
Use the ▼ or ▲ key to set the first calibration weight (eg. for 250 kg, se to "0").
•
•
Press the key shortly to confirm, now the second segment is flashing.
Use the ▼ or ▲ key to set this to "5".
•
•
Press the key shortly to confirm, now the third segment is flashing.
Use the ▼ or ▲key to set this to "2".
•
•
The thousands segment should be set, if necessary, to "0", in the same way as the
previous segments.
Confirm all other segments with ↵ until the NET pointer is flashing.
•
•
Lift the calibration weight (in the above mentioned example 250kg).
Press the ↵ key for about 4 seconds to confirm. The display counts down to "AF00".
•
The first calibration value is displayed. The first calibration weight can be lowered.
Press the ▲ key, the ~ pointer is flashing, the middle calibration value can now be
•
entered.
•
Press the key shortly, the right segment starts flashing.
44