MZ electronic EVV-A Instructions D'utilisation page 20

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Setting up the EVV-A
The setting of parameters occurs ONLY after the timeout interval; after 5
seconds elapse without any button being pressed, the parameter will be
accepted and stored.
1
Press
display will show one of the following
(depending on which display mode was
previously memorised):
AUT= AUTOMATIC
V= VOLTMETER
A= AMMETER
In the AUTOMATIC mode, the display
will show the voltage (in volt) for 8
seconds and then switch over to show
the current (in amperes).
In
the
VOLTMETER
instrument will display ONLY the
voltage (in volt) measured by the probe.
In the AMMETER mode the instrument
will display ONLY the current (in
amperes) measured by the probe.
Using the
possible to select one of the three
display modes.
If no button is pressed within 5 seconds, the last set display mode will be
memorised.
2
At this point for 3 seconds the display
will show:
The instrument will set up to display voltage, current or both if the AUTOMATIC display
mode has been memorised.
EVV-A
for three seconds. The
mode
buttons it is
the
20
English
Rev. 03 – 2008