3, step 1 - 3). 3. Remove the pre-filter, the filter cartridge with the screened cover and white filter fleece. Renew
the white filter fleece (6) during each cleaning process. 4. Remove all filter inserts. 5. Rinse the filter inserts
(7) and filter media with water until they are clean. 6. Empty the filter tank (10).
Note: Only carry out steps 7 to 8 during every third to fourth general cleaning. By mixing used and new sub-
strate media, the required bacteria cultures remain intact.
Caution: Do not overfill filter inserts as, otherwise, their accurate fit is no longer assured.
7. Leave one-third of the used EHEIM SUBSTRAT pro and EHEIM bioMECH in the filter cartridge. 8. Re-fill two-
thirds of the used EHEIM SUBSTRAT pro and EHEIM bioMECH. 9. If required, completely renew EHEIM MECH.
10. Re-insert all filters and filter inserts (chapter 3, step 8 - 10). 11. Clean the hose system using an EHEIM
universal cleaning brush (No. 4005570). 12. Insert the pre-filter (3) with the blue filter mat (1) (attach to parti-
tion wall's socket fi arrows). 13. The pre-filter flap (4) must be unobstructed. 14. Check the seals and, if re-
quired, treat them with EHEIM care spray (No. 4001000). 15. Attach the pump head (17) (observe fitting posi-
tion) and close the locking clips (9). 16. Put the filter system into operation (chapter 5, step 17 - 23).
Cleaning the pump chamber
8.3
Caution: The caramic axis may break. Clean carefully!
1. Disassemble the safety adapter (13) and the pump head (17) (chapter 3, step 1 - 3). 2. Turn pump cover (22)
and remove it. Grease the seal ring with EHEIM care spray. 3. Disassemble the pump wheel (21). 4. Clean pump
chamber, pump cover, pump wheel and lubrication duct with the EHEIM cleaning set (No. 4009560). 5. Pump
wheel (21) must be clean and unobstructed (arrows). Observe the installation position of the ceramic sleeve.
6. Insert the pump wheel (21) into the pump chamber. 7. Close pump chamber with the pump cover (22) ob-
serving the cutout and studs (arrows). 8. Disassemble the bracket (14) and the float (15) on the top side of
the pump head (17) and clean them. 9. Install the check valve (14/15) (observing the installation position; the
float must be unobstructed). 10. Attach the pump head (17) (observe fitting position) and close the locking clips
(9). 11. Put the filter system into operation (chapter 5, step 17 - 23).
9. What to do if . . .
Danger!
When working at the filter, assure that no water gets into contact with electrical interfaces. Disconnect the power
plug! In case of problems, visit our website www.eheim.de –
. . . Top part of filter can't be closed?
Cause
Filter inserts have been inserted wrongly.
Filter inserts are too full.
Partition not fitted properly.
Gasket not fitted properly.
. . . Top of filter leaks?
Cause
Closing clips not closed properly.
Sealing areas or gasket soiled.
Sealing ring not fitted,
inserted wrongly or damaged.
î
Solution
Push filter inserts and pre-filter in until they lie flush on top of each other.
Do not overfill filter inserts. If need be, clean the touching surfaces.
Push partition into the filter container until it engages correctly.
Insert correctly into the groove provided in the upper part of the filter.
Check for damage and if necessary replace.
Solution
Close all clips properly.
Clean seal areas and spray lightly with EHEIM silicone grease spray
(Order no. 4001000).
Insert sealing ring correctly or renew.
25