Terminology And Symbols Used In This Manual; Harrier Technical Specifi Cations; Intended Use And Applications - Aprimatic HARRIER Série Notice D'installation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Introductory notes / Technical specifi cations

3. TERMINOLOGY AND SYMBOLS USED IN THIS MANUAL

• OPERATING AREA: Zone around the area where the installation procedure is being carried out and where persons may be exposed
to safety and health hazards (Attachment I, 1.1.1 - EEC Directive 89/392);
• PERSON EXPOSED TO RISKS: Any person who is wholly or partially present in a hazardous area (Attachment I, 1.1.1
- EEC Directive 89/392);
• INSTALLER: Person in charge of installing, commissioning, adjusting, maintaining, cleaning, repairing and transporting
the device (Attachment I, 1.1.1 - EEC Directive 89/392);
• RESIDUAL HAZARD: A hazard that could not be eliminated or reduced during the design process.
!
Warning
Indicates information, instructions or procedures that can cause injury, death, or long term
health or environmental hazards if not observed correctly.
Caution
Indicates procedures or practices that can seriously damage to the machine or the product
if not carried out correctly.
Information
Provides information about particularly important matters: failure to respect these indications
may result in the guarantee being invalidated.
4. HARRIER TECHNICAL SPECIFICATIONS
4.1

INTENDED USE AND APPLICATIONS

The Harrier electro-mechanical unit is designed to operate (open and close) a barrier;
It is intended exclusively for use with vehicular traffi c.
Any other use is considered improper and therefore hazardous.
No other use is authorised by Aprimatic.
Caution
It is forbidden to use the product for any other purpose than the intended one.
It is forbidden to tamper with the product or modify it.
Only APRIMATIC accessories may be used when installing the product.
4.2
TECHICAL DATA FOR AVAILABLE VERSIONS
Version
Single phase power supply
Motor power
Consumption
Number of rotations slow shaft rpm
Number of poles
Reducer type
Max Torque (dynamic)
Operating time
Max. Barrier length
Max barrier length with skirt
Operating temperature
Lubrication
Use
E25-X25
Kw
0.18
A
1.4
23.3
4
MVF 49/P
1:60
Nm
40
sec.
1.8
m
2.5
m
°C
SHELL Trivela Oil SC 320 (synthetic oil)
- 16 -
E40-X40
E50-X50
230 V - 50 Hz.
0.18
0.15
1.4
2.7
17.5
9
4
6
MRVF 49/P
MVF 49/P
1:80
1:100
60
95
2.5
5
4
5
4
- 15 ÷ 60
continuous
E60-X60
0.24
2.0
4.6
4
MRVF 49/P
1:300
160
9.5
6
5

Publicité

Table des Matières
loading

Table des Matières