by frequent use (fi g.11). Proceed as follows:
- Loosen the control cam dowels;
- Adjust the cam in order to move the limit switch back or
forward by 2° or 3 °;
- Retighten the dowels in the defi nitive position.
Information
When adjusting the limit switch for the effects of frequent
use, the barrier should be in the normal working condition,
i.e. after being operated about ten times.
10. In addition, to ensure that the barrier works properly,
check that the lever roller operates at about 20-30 mm from
the bottom of the oscillating link slot.
11. If the barrier makes unusual swaying movements during
operation, adjust the balancing spring nut (fi g.12) in order
to increase the loading strain until the barrier movement is
linear when opening and closing.
!
Warning
Before adjusting the spring nut,
the barrier MUST BE moved to the open position in order
to discharge the spring.

9. EMERGENCY OPERATION

In case of malfunctions or mains interruptions, the barrier
can be operated manually using the special crank, as
follows:
1. OPEN THE MAINS SWITCH;
2. Open the side panel using the special key provided
(fi g.13-ref.1) - (when the panel is open, the safety micro-
switch (fi g.13-ref.2) inhibits motorised operations);
3. Insert the crank in the corresponding motor spindle
(fi g.13-ref.3) and rotate it until the barrier reaches the desired
position;
4. Remove the crank;
5. Close the side panel.
!
Warning
The panel must be closed, otherwise the safety micro-
switch inhibits motorised operation.
Spring
locking/adjustment nut
1
- 23 -