• Unplug the appliance from the mains supply after each use, or if a
fault is suspected.
• The electrical plug must not be removed from the socket by pulling
the cable.
• Never immerse the iron or steam tank in water or any other fluid.
• Do not leave the appliance exposed to weather conditions (rain, sun,
frost, etc.).
• With the aim of avoiding dangerous situations, any work or repair
that the appliance may need, e.g. replacing a faulty mains cable,
must only be carried out by qualified personnel from an Authorised
Technical Service Centre.
Important :
• This appliance reaches high temperatures and produces steam
during use, this could cause scalds or burns in case of improper
use.
• The steam hose, base station and in particular the iron can get hot
when used.
• Do not allow the power cable to come into contact with the soleplate
when it is hot.
• Never aim the steam at people or animals.
Description
1. Boiler´s cap
2. Iron pad
3. Mains
cable
and
4. Mains cable
5. Steam hose
6. "Steam ready" pilot light
7. "Refill boiler" pilot light
8. Illuminated main power button (0/I)
9. Variable steam control (*depending on the model)
10. Housing with internal steam generator
11. Temperature control knob
12. Steam release button
13. Iron pilot light
14. Soleplate
15. Steam button lock (*depending on the model)
16. Filling funnel
Preparations (A)
1. Remove any label or protective covering from the soleplate.
2. Place the appliance horizontally on a solid, stable surface.
3. Open the boiler´s cap (1). Fill the boiler carefully using always the
funnel, and close the cap firmly.
Filling with warm water reduces the waiting time for heating up.
Do not overfill the boiler.
4. Unwind the mains cable (4) fully and plug it into an earthed socket.
5. Switch the main power button (8) on (position "I")
6. The "Steam ready" indicator lamp (6) will light up after approximately
7 minutes, indicating that the appliance is ready to use.
7. This appliance has a water level sensor. The "Refill boiler" indicator
(7) will light when the boiler is empty.
Refilling the boiler
Attention! Risk of burns!
Be careful when opening the cap, steam may escape.
If the pilot lamp (7) illuminates :
1. Press the steam button (12) to check that no more steam is
generated. Only then the boiler should be refilled.
2. Set the appliance switch (8) to the off position ("0") and unplug the
steam station from the mains. Then wait for minimal 2 minutes.
3. Open the cap (1) carefully and slowly. Allow remaining steam to
escape.
4. Refill the boiler using always the funnel. Do not overfill the boiler.
5. If there is water left around the filling inlet, please dry with a towel
before closing the boiler.
6. Close the cap firmly.
Important:
• Normal tap water can be used.
To prolong the optimum steam function, mix tap water with distilled
water 1:1. If the tap water in your district is very hard, mix tap water
with distilled water 1:2.
You can inquire about the water hardness with your local water
supplier.
• To avoid damage and/or contamination of the boiler, do not use
perfumed water, vinegar, starch, descaling agents, additives or any
other type of chemical product.
Any damage caused by the use of the aforementioned products,
will make the guarantee void.
hose
storage
compartment
• The iron is not designed to rest on its heal. Please always position it
horizontally on the iron pad (2).
• During it first use the iron may produce certain vapours and odours,
along with white particles on the soleplate, this is normal and it will
stop after a few minutes
Setting the temperature
1. Check the ironing instruction label on the garment to determine the
correct ironing temperature.
2. Select the temperature (11):
•
••
•••
3. The indicator lamp (13) will remain lit while the iron is heating and go
out as soon as the iron has reached the selected temperature.
Tips:
• Sort your garments out based on their cleaning symbol labels,
always starting with clothes that have to be ironed at the lowest
temperatures.
• If you are not sure what the garment is made of then begin ironing at
a low temperature and decide on the correct temperature by ironing
a small section not usually seen when worn
Ironing with steam (B)
1. Turn the temperature selector (11) to the required setting
2. Set the amount of steam to suit your needs, using the variable steam
control (9) (depending on the model).
3. Press the steam release button (12) to release steam.
Attention:
When ironing on a lower temperature setting "•".
• If the appliance has variable steam control (9), set the variable steam
control to its lowest position ("–").
• If the appliance does not have variable steam control, press the
steam release button (12) only for a few seconds at a time when
ironing at lower temperatures.
In both cases, if you find that water is dripping out of the soleplate, set
the temperature selector (11) to a higher position (take care that the
garment can be ironed on this heat temperature setting).
Cork handle iron
(depending on the model):
To get permanent steam, press the lock button (15) and slide it
backwards until it locks. To switch off the permanent steam, slide the
lock button forward.
Important:
• The steam hose may get hot if you are ironing for long periods.
Ironing without steam
1. Set the required ironing temperature.
2. Begin ironing but without pressing the steam release button (12).
Vertical steam (C)
1. Set the temperature control to the "••" or "max" position.
2. You can steam iron curtains and hanging garments (jackets, suits,
coats...) by holding the iron in a vertical position and pressing the
steam release button (12).
Operate the iron vertically at a distance of 10 to 20 cm
Never direct the steam jet at garments that are being worn.
Never aim the steam at people or animals.
Cleaning the Boiler
To extend the life of your steam generator and to avoid any build up
of scale, it is essential that you rinse out the boiler after several hours
of use (approximately after 50 hours). If the water is hard, increase
the frequency.
Do not use descaling agents for rinsing out the boiler, as they could
damage it.
1. Check that the appliance is unplugged and cold for more than 2
hours.
2. Unscrew the boiler´s cap (1)
3. Empty the boiler above a sink by holding the appliance upside
down.
4. Fill the boiler with 500 ml of fresh water.
5. Shake the base unit for a few moments and then empty it completely
over a sink or bucket.
6. To obtain the best result, we recommend that this operation is done
twice
7. Close the cap
en
Synthetics
Silk-Wool
Cotton-Linen