Electrical connection

• Detach cover fastening screws and remove cover.
In the case of heaters with thermostat, remove the
cover complete with knob.
• Screw in safety union piece, insert connector, and
tighten pressure screw. The cable gland can be used
for cables between 9 and 17 mm.
Attention: To ensure high tightness IP 66 / IP 67,
expansion protection, and proper strain relief only
use the enclosed M 25 x 1,5 union piece.
230 V AC
ET-RDA-250 – 3000
ET-RDA with built-in thermostat
Install the cover with the marking upward!
230 V AC, DC
ET-RRU-500
Please note when connecting thermostatic devices!
• The thermostat is a sensitive component. Please be careful when attaching
the device!
• The connecting cables should not touch the housing of the thermostat and not
be installed below the regulator so that the switching function of the bi-metal
is guaranteed.
• before commissioning we recommend a functional test of the thermostat.
For this purpose turn the rotary knob until a clicking sound can be heard.
Heaters ET-RDA with built-in
thermostat, heat according
to the pre-set temperature.
This temperature can be
steplessly adjusted using the
thermostat knob. The opera-
ting status of the heater is
indicated by the signal light.
= frostfree
= + 5°C to + 30°C
• Connect according to the circuit diagram shown
below. Do not forget to connect the protective
conductor. Ensure that all terminal screws are well
secured.
• When connecting the heaters is to install an all-pole
disconnection from the network to provide. The
isolating device shall be at each pole of a contact
distance corresponding to the over voltage category
III have for full separation.
230 V AC, DC
ET-RRU-1000 – 3000
Start-up
As soon as the mains voltage is switched on the
heaters ET-RRU are in operation.

Surface temperatures

Surface temperature rise on the ribbed top edge of
the ribbed tube heaters during operation: ET-RRU,
ET-RDA max. 200°C.
The surface temperature is made up of the effective
temperature rise and room temperature.
Care must be taken to ensure that the heaters
are not covered. If covered there is a fire hazard.
400 V 3 (N) AC
ET-RRU-1000 – 3000
Remove bridges!
9