Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9 - Open commands

ALARM FUNCTION

WHO
5
Example:
If the remote control is active (Remote management / Telecontrol AI set on ON or USER), it is
possible – from the keypad or by telephone - to activate the burglar alarm by using the Open
Web Net code
or deactivate it with code:
WHO = 5 alarms, WHAT = 8 activation/ 9 deactivation.
ENTER AND SUB-DIVIDE
The following commands can be used both remotely and in the automation:
*5*8#.........##
*5*9#.........##
Where, instead of the dots, there will be the number of active zones required.
Example:
By entering the command:
the system will be enabled (if already enabled, it will remain the same);
zones 1, 2, 5 and 6 will be active;
the remaining zones 3, 4, 7 and 8 will be sub-divided.
These commands are useful when it is necessary to change the sub-division status while enabling
the system, for example from a connector or most importantly from a transponder reader (in this
case, the reader must be configured as a connector).
To carry out automations with the transponder readers, pay attention to the fact that if "connector
number 00" is used in the enabling/disabling automation, it will work at every enabling action,
from any device.
Instead, using a specific address and enabling from a transponder reader, the automation will
occur only if the transponder has MOD=1 and if it has been stored not only in the Unit but also
in the reader thereof. In fact, by doing so, the reader acts as a connector.
As for transponders produced from September 2005, this function will also be available in MOD=0.
160
WHAT
Function
Activation
Deactivation
(enables the system and changes the division)
(disables the system and changes the division)
WHERE
Value
Function
8
Not used in
this function
9
*5*8##
*5*9##
*5*8#1256##
WHEN
Value
Function
Not used in
this function
Value