Environmental Protection; Before Starting The Equipment; Connecting To Earth; Starting The Engine - Matrix PG 6000-D-Silent Traduction De La Notice Originale

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
Power class:
Max. altitude (above mean sea level):
Operating mode S1 (continuous operation)
The machine can be continuously operated with
the quoted power output.

6. Before starting the equipment

Important. The equipment must be filled with
engine oil and diesel fuel before it is started.
. Prepare and connect the battery (Important. The
battery is not included.) Secure the battery (Fig.
5/Item A) in the unit using the battery mounting
kit (Fig. 3/Item 20). First connect the red cable (+)
and then the black cable (-) to the battery.
. Check the diesel fuel level and top it up if
necessary.
. Make sure that the device has sufficient
ventilation.
. Inspect the immediate vicinity of the generator.
. Disconnect any electrical equipment which may
already be connected to the generator.

6.1 Electrical safety:

. Electric supply cables and connected
equipment must be in perfect condition.
. The generator is to be operated only with
equipment whose voltage specifications conform
with the generator's output voltage.
. Never connect the generator to the power
supply (socket-outlet).
. Keep the cable length to the consumer as short
as possible.

6.2 Environmental protection

G1
1000 m
. Dispose of soiled maintenance material and
operating materials at the appropriate collection
point.
. Recycle packaging material, metal and plastics.

6.3 Connecting to earth

The housing is allowed to be connected to earth
in order to discharge static electricity. To do this,
connect one end of a cable to the earth
connection on the generator (Fig. 2/Item 14) and
the other end to an external earth (for example
an earthing rod).
7. Operation

7.1 Starting the engine

. Check whether the mechanical switch (Fig. 6/
Item A) is set to "RUN".
. Set the ON/OFF switch (Fig. 2/Item 18) to the
"ON" position using the key.
. Pull the decompression cable (Fig. 2/Item 7) and
turn the ON/OFF switch to "Start" using the key.
Release the decompression switch after approx. 5
seconds and the engine will start.
. When the engine is running, turn the ON/OFF
switch to "ON".
. If the engine does not start straight away
(particularly if the tank was previously empty or
after you have replaced the diesel filter), repeat
the starting procedure by pulling the
decompression cable again.

7.2 Connecting consumers to the generator

. Set the selector switch (Fig. 2/Item 11) to the
left to use 230V~ sockets.
. Set the selector switch (Fig. 2/Item 11) to the
17

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

160.100.143

Table des Matières