. If you use the diesel generator regularly, you do
not need to take any precautions since the
change to winter diesel takes place automatically.
. If you do not use the generator for a lengthy
period during autumn, but then wish to use it
again in winter, we recommend that you keep
the tank almost empty or drain it as described in
point 8.4.
. Ask at your filling station when you should
change to winter diesel and fill the tank with
winter diesel before the onset of outdoor
temperatures of between -3°C and -10°C.
. If the diesel fuel still freezes, you must move the
diesel generator to a place where the
temperature is approximately +10°C for a period
of approximately 12 hours.
. If the tank is between halfway and full with
normal diesel fuel, this should then be drain as
described in point 8.4.
. Then fill the tank with winter diesel.
. If the tank is between empty and half-full,
simply fill it up with winter diesel.
10. Brake
To prevent the movement of generator on slope
or uneven ground, enter the brake lever(23)
down, then the brake(24) forces the rollers (6).
Please note: the angle of slope is not more than
15 degrees.
11. Disposal and recycling
The unit is supplied in packaging to prevent its
being damaged in transit. This packaging is raw
material and can therefore be reused or can be
returned to the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic.
Defective components must be disposed of as
special waste. Ask your dealer or your local
council.
20