Mains voltage U
1
Tolerance U
1
Mains frequency
Delayed fuse
Power consumed
Mains connection Zmax
cos Phi
Welding current range
X (duty cycle)
According to standard IEC
60974-1
Open-circuit voltage U
0
High-frequency
power-on
voltage Up
Maximum welding gas pressure
EMC emissions class
Performance
Consumption in stand-by
Overvoltage class
Degree of pollution according to
IEC 60664
Certifications
Degree of protection
Weight
Dimensions (WxDxH)
This equipment complies with standards IEC 61000-3-12 and IEC61000-3-11 provided that impedance of the supply line in the PCC is less than
Zmax shown in the table.
The fitter or the unit user are responsible for ensuring, consulting the distribution network operator if necessary, that the equipment is connected
to a power supply with a maximum system impedance lower than Zmax.
The tables in section 2.3 show the technical data of welding power sources for the two processes used in the field of industrial automation, which
are the TIG or Plasma Welding (PW) processes. When in manual mode, the power sources are able to weld using a coated electrode (MMA). For
more details, refer to manual 3301017.
(*) Refer to the value given for Item No 465.01.
3301229
TECHNICAL SPECIFICATIONS TABLE
380
TIG
3 x 400 V
±15%
50/60 Hz
16 A
10 kVA 40
10.4 kVA 30%
8.3 kVA 60%
9.1 kVA 60%
7 kVA 100%
8.7 kVA 100%
0.087 Ώ
0.99
3 ÷ 340 A
10 ÷ 250 A
340 A 40%
250 A 30%
300 A 60%
230 A 60%
270 A 100%
210 A 100%
57 V
10.3 kV
6 bar / 87 psi
A
>85%
<50 W
III
3
CE, EAC, UKCA
IP23S
69 Kg
560x950x1010 mm
PW
Supply voltage
Power consumed
16 A
Nominal cooling power 1
Nominal maximum
pressure
(*)
N.A.
1683
1 x 230 V - 50/60 Hz
1.2 A
1.5 kW
l/min
0.35 Mpa/3,5 bar
CE, EAC, UKCA
IP23S
20 kg
394x218x225 mm