CONTINUOUS AND INTERMITTENT SOUND SIGNAL WITH BTICINO ITEMS
CODE
BTicino
Pt
5005/1N
L4351/12
N4351/12
S
It
Ra
Rt
TRSF
F93/12/24
The diagrams show some auxiliary circuits that enable the repetition of the sound signal
in the "temporary" mode and in the "continuous" or "intermittent" mode, necessary when
the calls must have an "emergency" or "alarm" characteristic (e.g. from bathrooms, hospital
bedrooms, technological rooms, ...).
When there are ongoing calls, the auxiliary contact of the display unit (terminals 1-5), closed
as long as the call pushbutton remains pressed, activates bell S in the "temporary" mode.
Instead, in the "continuous" mode, bell S is activated by contact Rt1 of the auxiliary mo-
nostable relay Rt. In the "intermittent" mode, sound signal S is activated by contact Ra1 of
the auxiliary relay Ra, which is activated by intermittence It. In these two last two cases,
the operator can silence the bell by pressing pushbutton Pt. The bell will be activated again
by the next call.
DESCRIPTION
item
Bell silence 1P break contact pushbutton (NC)
L4034
Living International series
N4034
Light series
4505/1
Living series
Magic series
Bell
Living International series
Light series
4351
Living series
5031N
Magic series
5329
Intermittence - Magic series
5882
Monostable auxiliary relay 3NO - Magic series
5884
Monostable auxiliary relay 3NO - Magic series
Safety transformer (4 DIN modules) 25VA 230/12/24V