4.4 - Power supply

• Nominal voltage: 3,2 ... 6V DC
• Average current consumption: < 50 µA. (depends on product configuration)
4.5 - Optional connecting AXONIC with Pulse-Box to integrator unit (optional power supply)
The Pulse-Box offers the following functions:
• Power supply of AXONIC independently of the integrator.
• Galvanic insulation of AXONIC from the integrator.
Before connecting, make sure that the pulse of AXONIC and integrator match!
Connection of AXONIC with Pulse-Box to an integrator according to mounting instructions: respect polarities!
Characteristics of pulse exit:
• Version:
• Polarity:
• Duration of impulse:
• Maximum input voltage:
• Max. input current:
• Voltage drop when switched on:
• Resistance when switched off:
• Maximum pulse frequency:
• Maximum cable length:
5 - FUNCTION CONTROL OF AXONIC
The AXONIC flow sensor is equipped with a LED in order to perform a simple functional check. The signal sequence
depends on operation conditions and will be repeated any 10 as follow:
Information
Flow detected
Air in pipe / US Asic alarm
Low signal amplitude alarm
Max flow alarm
Back flow alarm
Product in test mode
Product configuration un-locked
Product configuration corrupt
Function control at the calculator:
A functional control and plausibility check shall be done by observing the indications of flow rate and volume index, see
calculators manual and operating instructions.
Putting into operation:
After successful functional test AXONIC is now ready for use and final technical inspection.
While Itron strives to make the content of its marketing materials as timely and accurate as possible, Itron makes no claims, promises,
or guarantees about the accuracy, completeness, or adequacy of, and expressly disclaims liability for errors and omissions in, such ma-
terials. No warranty of any kind, implied, expressed, or statutory, including but not limited to the warranties of non-infringement of third
party rights, title, merchantability, and fitness for a particular purpose, is given with respect to the content of these marketing materials.
© Copyright 2019 Itron. All rights reserved. HE-0058.4-ig-ML-04.20 17768-AC
• Peak current consumption Imax: < 3 mA
• Pulse length increase of AXONIC's pulses.
• 2 wire pulse output
Open collector
non reversible (respect connecting diagram)
135 ±35 ms
30 V DC
27 mA
≤ 0.3 V at 0.1 mA, ≤ 2.0 V at 27 mA
≥ 6 MΩ
1Hz
10 m
Number of flashes
1
2
3
4
5
Permanent flashing
Flash sequence as above 1...5,
but inverted
Permanent ON
Join us in creating a more resourceful world.
To learn more visit itron.com
LED
Signal/Period (Repetition)
20ms (LED ON) / 10s
20/500ms (LED ON/OFF) / 10s
20/500ms (LED ON/OFF) / 10s
20/500ms (LED ON/OFF) / 10s
20/500ms (LED ON/OFF) / 10s
20/500ms (LED ON/OFF) / permanent
500/20ms (LED ON/OFF) / 10s
Permanent (LED ON)