MAINTENANCE
7.4.3
CHANGING THE PUMP EXHAUST FILTER
WARNING: This operation must be carried out by qualiied personnel.
1) Remove the stainless steel panel on the rear of the machine.
2) 8, 12,18 and 25 mc/h pumps unscrew plug (A) on the pump body using pliers.
3) Remove ilter (B) from its seat.
4) Insert the new ilter after checking to make sure 'O-ring (C) is in the correct position.
5) Reit the cover by ixing spring (D) on the ilter projection (E).
7.4.4
CHANGING THE LID GASKET AND RED SILICONE
1) Open the plexiglas cover.
2) Remove cover gasket (F) or the red silicone strip (G) and clean the seats to remove dirt.
3) Insert the new gasket pushing it deep into the cavity all the way.
4) Run a loadless cycle so that the gasket its irmly into its seat.
Operating and service manual / Mode d'emploi et d'entretien
Manual de uso y mantenimiento / Ed. 01 - 2011
2940 Hwy 14 W, Rochester, MN 55901
A
•
F
•
C
•
•
•
D
E
G
•
38
VACUUM PACKING MACHINE
CONDITIONNEUSE SOUS VIDE
MAQUINA DE VACÍO
B
REV. 00 - Cod.: 1500386