MAINTENANCE
7.2

PROGRAMMED MAINTENANCE

FREQUENCY
Before each start up
Weekly
Every 3500
operating cycles (about 100
hours of service)
Every two oil changes
Every 12 months
7.3
CARE AND CLEANING OF THE VACUUM PACKAGING MACHINE
ELECTRIC HAZARD!
Danger of electric shock ! Remove the ma-
chine plug from the power socket. Do not use
water or steam jets.
DANGER! Danger of burns: if alcohol-ba-
sed or inlammable disinfectant products
are used, ventilate the area. Do not use naked
lames near the machine! Do not smoke!
ATTENTION! Danger of injury! Use personal
protective equipment. Do not use caustic
products, acids or aggressive products such
as muriatic acid. Read the instructions on the
detergent product or disinfectant pack carefully.
WARNINGS! Use alcohol-based disin-
fectants.The machine must be cleaned and
disinfected every time after use.
Operating and service manual / Mode d'emploi et d'entretien
Manual de uso y mantenimiento / Ed. 01 - 2011
2940 Hwy 14 W, Rochester, MN 55901
MACHINE PART
Pump
Power cable
Plexiglas cover
Silicone
and Plexiglas cover gasket
Machine and vacuum chamber
Sealing bar connection wire
Sealing bar
Pump
Pump
Pump
Pump
A
Check the oil colour and level; top up the level, or
change it completely if the colour is dark or whitish.
Check to make sure it is intact, replace if damaged
(Contact a specialist Service Centre).
Check to make sure it is intact; if cracks or stre-
aks are present, contact Customer service for
replacement.
Check to make sure they are inserted properly in
their seats; replace if damaged.
Clean to remove impurities, oil and grease.
Check to make sure it is connected.
Clean the upper part with a damp cloth.
Check dehumidiication cycle.
Change the pump oil
(call a specialist Service Centre).
Change the pump exhaust ilter (A)
(call a specialist Service Centre).
Change the pump oil.
(call a specialist Service Centre).