F-3
DIAGRAMME POUR LE BRANCHEMENT EN STYLE SCOTT DE LA AC-1200
DEUX MACHINES EN PARALLÈLE EN CONNEXION SCOTT AVEC DEUX AUTRES MACHINES EN PARALLÈLE
POUR L'ANGLE DE DÉPHASAGE SOUHAITÉ, INTERCONNECTER LES MACHINES (TEL QU'ILLUSTRÉ CI-DESSOUS).
LES DEUX ANGLES DE DÉPHASAGE DEVANT ÊTRE IDENTIQUES.
TRAVAIL
N.B.
ÉLECTRODE
4/O CÂBLE
N.B.
ÉLECTRODE
TRAVAIL
NOTES:
N.A.
POUR OBTENIR UN ORDRE DE PHASE NORMAL SUR LES ARCS DE SOUDAGE, L'ORDRE DE PHASE DE LA LIGNE D'ENTRÉE DOIT ÊTRE A-C-B.
N.B.
LES CÂBLES D'ÉLECTRODE DE MACHINES EN PARALLÈLE DOIVENT ÊTRE BRANCHÉS SUR UNE PRISE DE MÊME VALEUR.GE TAP.
N.C.
NOMBRE DE CÂBLES 4/0 BRANCHÉS : 1 SUR LA PRISE MINIMUM ; 2 SUR LA PRISE MOYENNE ; 3 SUR LA PRISE MAXIMUM.
DIAGRAMMES
C
B
L2
P1
L1
4/O CÂBLES
N.C.
TRANSFORMATEUR DE
CONTRE-DÉROULEMENT
EN DÉRIVATION
ARC DE TRAÎNAGE
L2
P1
L1
C
B
LIGNES D'ALIMENTATIONS TRIPHASÉES (N.A.)
IDEALARC
À LA MASSE CONFORMÉMENT AU
CODE ÉLECTRIQUE NATIONAL
A
L2
100
90
80
L1
4/O CÂBLES
N.C.
TRANSFORMATEUR
PRINCIPAL
ARC MENEUR
L2
100
90
80
L1
A
À LA MASSE CONFORMÉMENT AU
CODE ÉLECTRIQUE NATIONAL
AC-1200
®
TRAVAIL
N.B.
ÉLECTRODE
4/O CÂBLE
N.B.
ÉLECTRODE
TRAVAIL
A.01