Télécharger Imprimer la page

Inspection Of The Breaker - Canon imagePRESS C165 Guide Rapide

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Inspection of the Breaker

This machine has a breaker that detects excess current or leakage current. Make sure to test the breaker once a month
by following the procedure below.
1
Turn OFF the main power�
• Make sure that the main power is turned OFF, before
inspecting the breaker.
2
Push the test button located on the rear of the
machine�
• Push the test button with the tip of a ball-point pen or a
similar object. Briefly push the test button.
3
Confirm that the breaker lever is switched to the
OFF position�
• If the breaker lever is not switched to the OFF position,
repeat step 2. If the breaker lever is not switched to the
OFF position, despite carrying out the above procedure
two or three times, contact your local authorized Canon
dealer.
4
Switch the breaker lever to ON�
5
Turn ON the main power�
Cleaning and Maintenance
27

Publicité

loading