Aprimatic RAIDER Instructions Pour L'installation page 34

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Operating logic
SAME CYCLE IN ALL LOGIC TYPES
Gate status: CLOSED GATE
START pulse
STOP pulse
Opening safety
Photocell triggered
Gate status: GATE BLOCKED WHEN OPENING
START* pulse
* if after meeting an obstacle when opening, CLOSES (slowly).
* if after meeting an obstacle when closing, OPENS (slowly)
STOP pulse
Opening safety
Photocell triggered
Gate status: GATE STOPPED WHEN CLOSING
START pulse
* if after meeting an obstacle when opening, CLOSES (slowly).
STOP pulse
Opening safety
Photocell triggered
DIFFERENT CYCLE IN LOGIC CYCLE TYPES
Gate status: DURING OPENING
LOGIC
PULSE/SIGNAL
0-1-
START pulse
2-
START pulse
3-4-
START pulse
ALL
STOP pulse
ALL
Opening safety
ALL
photocell triggered
ALL
Obstacle encountered
on opening
Status of the gate: DURING THE PAUSE WITH THE GATE OPENS
LOGIC
PULSE/SIGNAL
0-
START pulse
1-
START within the
fi rst 3 seconds
2-3-4-
START* pulse
* In logic type 2, after encountering an obstacle when closing, stops the gate until a new START
(slowly).
ALL
STOP pulse
ALL
Opening safety
ALL
Photocell triggered
Status of the gate: DURING CLOSING
LOGIC
PULSE/SIGNAL
0-1-2-3-
START pulse*
3-4-
START pulse*
*After encountering an obstacle on opening
ALL
STOP pulse
ALL
Opening safety
ALL
Obstacle encountered
on closing
0-1-2-3-
photocell triggered*
4-
photocell triggered*
*after encountering an obstacle on opening
OPEN
Inhibits the signals: stops the operator.
Inhibits the signals: stops the operator.
Ignored.
CLOSES.
Inhibits the signals: stops the operator.
Ignored.
Ignored.
CLOSES
Inhibits the signals: stops the operator.
Ignored.
Ignored.
RESULT
Ignored
Changes direction (CLOSES AGAIN)
Stops the gate until a new START pulse is given
Stops the gate until a new START pulse
Goes back for 2 seconds and stops the gate until a new START pulse is
given
CLOSES (slowly).
Ignored.
Goes back for 2 seconds and stops the gate until a new START pulse
CLOSES (slowly).
RESULT
Ignored
Stops the gate until the new start pulse
Closes ignoring the pause period.
Stops the gate until a new START pulse (ignores pause period)
Ignored.
Stops the gate until the photocell is freed (ignores the pause period).
RESULT
Change direction (OPENS AGAIN)
Stops the gate until a new START pulse
Stops the gate until a new START
Stops the gate until new START pulse
Ignored
OPENS AGAIN (slowly)
Change direction (OPENS AGAIN)
Stops the gate until a new START pulse
Stops the gate until a new START pulse
- 34 -
CLOSES
CLOSES
CLOSES
CLOSE pulse
CLOSES
OPENS AGAIN.
CLOSE pulse (slowly).
CLOSES
CLOSES.
CLOSES (slowly).