3.2
ELECTRICAL CONNECTION PREPARATION
!
Warning
The system should be installed by qualifi ed personnel and comply with regulations in force in the country of use (regulation
CEI 64 - 8/EN 60335-1).
The metallic components of the structure (i.e. the gate and pillars) must have an earth connection.
Prepare the electrical connection of the controller and safety devices in accordance with the lay-out in fi g.5. Please heed
the warnings provided in this manual and comply with the instructions attached to the installed components. Prepare the
cableways (external or buried) up to where the devices will be installed .
The electric component box should be fully sealed and should be placed at least 30 cm from the ground. Cable
outlets should point downwards. The cableway joints to the box should be sealed to prevent the entry of dampness,
insects or small animals.
POWER SUPPLY: 230V AC - Cable 3x1.5mm
in accordance with the length of the line.
If a protective sheath needs to be applied to the automation power supply cable, apply it before connecting the
cable to the junction boxes.
IMPORTANT! Install a main switch upstream on the line multi-pole disconnection with a minimum contact opening of 3 mm.
(Connect this to a 6 A - 30 mA differential overload switch).
The command and control accessory devices and the emergency button should be placed within sight of the automation,
away from moving parts and at a minimum height of 1.5 m from the ground.
Fig. 5
5
7
3x0.75 Ø
2x1 Ø
1 RAIDER operator
2 Controller
3 Radio receiver
4 Twin-channel transmitter
5 433.92 MHz antenna
6 Flashing light
* Optional accessories (see sales brochure)
2
(minimum cross-section). The cable cross-section should be calculated
SYSTEM INSTALLATION DIAGRAM
6
9
1
2x1.5 Ø
7 Photocell pair
8 Key switch
Proximity reader*
Card reader*
Internal push button panel*
9 Electric lock*
1
2
3
2x1.5 Ø
10A
lc= 30mA
- 23 -
Preparatory steps
8
7
3x0.75 Ø
3x0.75 Ø
4