Maintenance and cleaning

Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries.
Protective measures:
• Prior to reaching into the water, disconnect the power supply to all units used in the water.
• Disconnect the power plug prior to carrying out work on the unit.
Important!
This units housing can not be opened for inspection. Opening the housing voids
!
warranty and can cause Death or severe injury. Follow cleaning instructions for routine cleaning.
Cleaning the unit
If necessary, clean the unit with clear water using a soft brush.
• In the event of stubborn furring (calcium deposits), a common household cleaner free from vinegar and chlorine can be
used. Subsequently, clean the pump thoroughly using clear water.
• Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the
function.
Storage/Winterization
The unit is frost resistant to -4°F (- 20 °C). Should you store the unit outside of the pond, clean it thoroughly with a soft
brush and water, check it for damage, then store completely submerged in a container of water. . Do not submerge the
power plug in water!
Disposal
Do not dispose of this unit with domestic waste! Disable the unit beforehand by cutting off the cables. Further
information about the recycling of this product can be obtained from your local municipal authority.

Spare parts

The use of original parts from OASE ensures continued safe and reliable operation of the unit. Please visit our website for
spare parts drawings and spare parts. www.oase-livingwater.com
A damaged unit cannot be repaired and must be put out of operation. Dispose of the unit in accordance with the
regulations.
Troubleshooting
Never open the housing! Only allow a qualified electrician to replace the power cable!
Issue
Unit does not run
Insufficient fountain height
Unit switches off after a
short period of operation
Questions, problems, missing parts?
Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email
us at customercare@oase-livingwater.com. Or visit our website at www.oase-livingwater.com
Cause
No mains voltage
Rotor blocked
regulator closed too far
filter housing soiled
air in the hose
rotor soiled
hose blocked or defective
hose kinked
rotor worn
filter clogged
Water temperature too high
Solution
check mains voltage
rinse the vane from the front
set regulator
clean filter housing
vent hoses
clean
clean hose or replace
check hose and replace if necessary
replace rotor
clean filter