Important; Maintenance And Cleaning - Oase BioPress 4000 Notice D'emploi

Masquer les pouces Voir aussi pour BioPress 4000:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
- GB -
Start-up
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
− Prior to reaching into the water, disconnect the power supply to all units used in the water.
− Disconnect the power plug prior to carrying out work on the unit.
Attention! Never operate the unit with a water pressure of more than 0.2 bar!
Figure C:

Important:

− Switch the pump on first, then the UVC clarifying unit.
− Do not operate the unit without water flowing through.
− The unit switches on automatically when power connection is established.
Switching on: Connect power plug to the socket.
− The control lamp is lit.
− The flow indicator flap in the transparent stepped hose adapter in the outlet moves.
Note:
− After a new installation, the unit only reaches its full biological cleaning effect after a few weeks.
− The full effect on bacteria is only reached as from a water temperature of + 10 °C.
− In the event of overheating, the installed temperature monitor switches the UVC lamp off automatically, the lamp
automatically switches on again once cooled down.
Check all connections for leaks.
Switching off: Disconnect the power plug.

Maintenance and cleaning

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
− Prior to reaching into the water, disconnect the power supply to all units used in the water.
− Disconnect the power plug prior to carrying out work on the unit.
Note:
− Check and clean the water outlet into the pond at regular intervals.
− Clean the filters at regular intervals (e.g. every four weeks), however, at the latest when cloudy or dirty water from
the water outlet returns to the garden pond.
− Carry out quick cleaning first. Should this prove insufficient, clean the entire unit.
− A blocked filter could lead to leakages.
− Never use chemical cleaning agents.
Quick cleaning (D)
− Switch off the filter pump.
− Remove hose from the filter outlet by turning off the union nut (1).
− Remove hose from the filter inlet by turning off the union nut and screw on the filter outlet (2).
− Screw a dirt drain hose with stepped hose adapter on the filter inlet.
− Switch on the filter pump.
− Vigorously pull on the cleaning handle and „pump" several times (3). In this manner, the foam filters are
mechanically cleaned until the draining water is clear.
− Switch off the filter pump.
− Remove the dirt drain hose and correctly reconnect the hoses for normal operation (Figure A).
Full cleaning (E)
− Disconnect all hoses by turning off the union nuts (1).
− Open the closing clamps of the filter container (2).
BioPress 4000: Hold the filter container at the hold-down element and lift off cover including the foam filter pack-
age (3).
BioPress 6000/10000: Lift off cover including foam filter package (2)
− Place the cover upside down onto a soft, clean surface, so that the foam filters with the press ring face up (4).
− Remove the press ring by undoing the nut from the pulling rod (4).
To remove the nut, hold the pulling rod using combination pliers.
Note: Do not pull the pulling rod out of the cover.
− Pull off the foam filters (5).
12

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Biopress 6000Biopress 10000

Table des Matières