Troubleshooting

9
Troubleshooting
Fault
Device does not
function, LED does
not glow.
The device does not
cool (plug is inserted,
"POWER" LED is lit).
The device does not
cool (plug is inserted,
"POWER" LED flashes
orange, display is
switched off).
The display shows an
error message (e.g.
"Err1") and the
appliance does not
cool.
10

Disposal

➤ Place the packaging material in the appropriate recycling waste bins wherever
possible.
M
If you wish to finally dispose of the product, ask your local recycling centre
or specialist dealer for details about how to do this in accordance with the
applicable disposal regulations.
20
Possible cause
Battery voltage is too
low.
No voltage present in
the AC voltage socket.
The device fuse is
defective.
The integrated mains
adapter is defective.
Defective compressor.
Battery voltage is too
low.
The appliance has
switched off due to an
internal fault.
Suggested remedy
Test the battery and charge it as needed.
Try using another plug socket.
Replace the device fuse, see chapter
"Replacing the device fuse" on page 18.
This can only be repaired by an
authorised repair centre.
This can only be repaired by an
authorised customer services unit.
Test the battery and charge it as needed.
This can only be repaired by an
authorised repair centre.