Transport of the machine
Rocker lock
• To transport the rocker circular saw lock in place
the rocker lock in position (1) and pull on the handle
(2).
1
m Electrical connection
Check electrical connection cables regularly for
damage. Ensure that the connecting cable is not at-
tached to the mains when you are checking it.
Electrical connecting cables must correspond to the
relevant VDE and DIN regulations. Only use con-
necting cables with the code H 07 RN.
The type designation must be printed on the con-
necting cable by regulation.
Faulty electrical connecting cables
Insulation damage often occurs at electrical connect-
ing cables.
Causes include:
• Pinch points when connecting cables are run
through window or door gaps.
• Kinks resulting from incorrect attachment or laying
of the connection cable.
16
GB
www.scheppach.com / service@scheppach.com / +(49)-08223-4002-99 / +(49)-08223-4002-58
2
• Cuts resulting from running over the connecting
cable.
• Insulation damage resulting from forcefully pulling
out of the wall socket.
• Cracks through aging of insulation.
Such defective electrical connection cables must not
be used as the insulation damage makes them ex-
tremely hazardous.
Three-phase motor 400 V/ 50 Hz
Mains voltage 400 Volt / 50 Hz.
Mains voltage and extension cables must be 5-lead
(3P + N + SL (3/N/PE).
Extension cables must have a minimum cross-sec-
tion of 1.5 mm² (≤ 25m).
Extension cables must have a minimum cross-sec-
tion of 2.5 mm² (> 25m).
Mains fuse protection is 16 A maximum
When connecting to the mains or relocating the ma-
chine, check the direction of rotation (swap polarity in
the wall socket if necessary).
Turn pole inverter in the machine socket.
Motor-brake appliance
The brake slowes down the motor of the saw shaft
within 10 seconds.
The electrical braking is interrupted after maximum
14 seconds.
In case the braking takes more than 10 seconds the
machine should not be used again, as the brake is
defective. The machine implicitly needs to be discon-
nected from the power supply. Only an electronic spe-
cialist should be instructed to repair this malfunction.
Operating mode / Switch-on duration
The electrical motor is dimensioned for operating
mode S6 - 40 %.
S6 = pass operation with load exposure
40% = related to 10 min. 4min. load; 6min. pass oper-
ation
If the motor gets overcharged, it automatically
switches off, as a winding thermal switch is built in the
winding of the motor. After a cool-down period (time
varies) the motor can be switched on again.
Check electrical connection
• Switch on the machine with the power switch, the
motor runs up.
• Check the direction of rotation!
• Three-phase AC motors must be checked for their
direction of rotation in the event of a new connec-
tion or change of location. If necessary, the direc-
tion of rotation must be changed with the phase
inverter (Fig. A)
• Upon switching off the saw shaft is slowed down
within 10 seconds.