28
ENGLISH
Product code
General specifications
Output voltage
Output waveform
Nominal battery voltage
Cont. power at 40 °C, cos phi 1
Peak load
Connection
Parallel configuration
3-Phase configuration
Efficiency
Display/read-out
Dimensions, hxwxd
Weight
Approvals
Technical specifications
Technology
Battery voltage range
Low battery voltage, switches off at
Low battery voltage, switches on at
High battery voltage, switches off at
High battery voltage, switches on at
Input current (nominal load)
No-load power consumption
Minimal DC fuse (slow blow)
Minimal cable size
Harmonic distortion typical
Cos phi
Temperature range (ambient temp.)
Cooling
Protection degree
Protections
AC input transfer system
AC input
Transfer time speed
Transfer voltage range
Transfer frequency range
Options
Remote control
AC Master 12/3500-230
28013500
230/240 Vac (± 3%) –
50/60 Hz (± 0,1%)
True sine
12 V
3500 W
4500 W (3 s) ; 6000 W (0,2 s)
Hard wire / Continental European
(SCHUKO)
Up to 15 units
Up to 3x1 (1 unit per phase)
90%
1 x LED
283 x 128 x 496 mm
10 kg
CE, Safety: EN60950-1, E-mark:
CISPR25, ISO7637-2, EMC: EN
55014-1, EN 55014-2, EN61000-3-2, -
3-3, EN61204-3, EN 61000-6-1, -6-2, -
6-3, -6-4, IEC 61000-4-2, 3, 4, 5, 6, 11
High frequency
10,0 V – 16,0 V
10,0 V
12,5 V
16,0 V
15,0 V
350 A
On mode: < 3,6A @ 12 V
Energy Saving mode: < 1,4 A @ 12 V
400 A
120 mm²
< 3 %
All power factors allowed
-20 °C to 60 °C, derating > 35 °C
Fan
IP21 (if horizontally wall mounted)
Over temperature, over load, short
circuit, high/low battery voltage, AC
overcurrent (breaker)
20 A (circuit breaker)
Inverter to AC input: 8~10 ms
AC input to Inverter: 16~50 ms
230/240 Vac (± 12,5%)
47-57 Hz (50 Hz) / 53-63 Hz (60 Hz)
Yes