►►7.1. HANDLING:
en
See Fig. 7
The heater can be easily handled by the wheels
it
and handles. To handle the heater better:
de
►7.1.1. Release the handles from their closed
position (pull the locking pin outwards).
es
►7.1.2. Lock the handles in a handling position.
►7.1.3. Move the heater by lifting the handles
fr
and making it slide on its wheels.
nl
►7.1.4. Put the handles back into their closed
position.
pt
►►7.2. TRANSPORT:
da
See Fig. 8
fi
It is possible to lift and move the heater from the
specific anchoring points.
no
sv
►►8. DISPLAY ERRORS
pl
See B Fig. 3
ERROR
ru
cs
F0
1. The "ON/OFF" switch is turned "ON"
(|) when the heater is plugged in
hu
sl
F1
1. No fuel
tr
2. Fuel is contaminated
hr
lt
3. Photocell is dirty or damaged
lv
4. Fuel filter is dirty
et
5. Ignition error
ro
F2
1. Interrupted cable
sk
2. Sensor is damaged
bg
F3
1. Internal heater overheating
uk
2. Antitilting sensor intervent
bs
el
F4
1. Incorrect voltage
zh
FF
1. No fuel
2. Dirty fuel filter
3. Dirty or defective photocell
4. Dirty or defective nozzle
5. Anti-tilting sensor trip
www.MCS-Heater.com
CAUSE
TEMPERATURE CONTROL SENSOR ERROR
INCORRECT VOLTAGE
NO SWITCH-ON AFTER THREE ATTEMPTS
800 292-3279
►►7.3. STORAGE:
IN ORDER TO KEEP THE HEATER IN
THE
BEST
WE
RECOMMEND
PROCEDURE BELOW:
►7.3.1. Empty the fuel from the tank by
removing the discharge plug at the bottom
of the tank. Dispose of the fuel appropriately
and in line with current standards.
►7.3.2. If you notice any residue, pour clean
fuel into the tank and rinse again.
►7.3.3. Close the drain plug and the tank plug.
►7.3.4. In order to keep the heater in the best
conditions possible, we recommend placing
it in a dry place away from potential external
damage.
OPERATION ERROR
1. After disconnecting the heater, see that the
switch is in the "OFF" (0) position, plug the
heater in and turn the switch "ON" (|)
PHOTOCELL ERROR
1. Turn the switch "OFF" (0), refill the fuel tank
2. Turn the switch "OFF" (0) empty and refill
the fuel tank. Clean the filter using clean
fuel, do not damage the filter (SEE PARA.
6)
3. Contact the technical service center
4. SEE PARA. 6
5. Contact the technical service center
1. Contact the technical service center
2. Contact the technical service center
THERMOSTAT ERROR
1. Turn the heater off, wait until it is cooled
down
2. Place the heater on a level and stable
surface
1. Check voltage of your electric supply
system
1. Contact the technical service center
2. Contact the technical service center
3. Contact the technical service center
4. Contact the technical service center
5. Contact the technical service center
POSSIBLE