Technical Data for TRL blower
Motor rating, kW (hp)
Electrical supply,V/Hz
Amp. consumption
Min. fuse rating
(approx.)
Motor, r.p.m. (nominal)
Motor
Weight motor
included, kg
Weight motor
excluded, kg
Rotor, r.p.m.
Num. of rotors
Type of pipelines
Heating of air, °C
Technical Data for Rotary Valve CAD
Tekniske data
Numbers of pockets in the
rotor
Rotor, r.p.m.
Motor rating, kW (hp)
Electrical supply, V/Hz
Amp. consumption
Motor, r.p.m. (nominal)
Motor
Weight motor included, kg
Weight motor excluded, kg
16
TRL 20
TRL 40
TRL 55
1,5(2)
3(4)
4(5,5)
3,4
6,3
8,5
10
16
16
35
67
76
18
41
43
2850
2850
2850
1
1
1
2
3
4
CAD 20
6
65
0,37(0,5)
3x380/50
0,82
1500
T.E.F.C. foot mounted IEC/DIN
34
26
TRL 75
TRL 100 TRL 150 TRL 200 TRL 300 TRL 500
5,5(7,5)
7,5(10)
3x380/50
11,5
15,5
20
25
3.000
T.E.F.C foot mounted IEC/DIN
96
129
47
69
2850
3650
1
1
OK/OKR 160 (Diametres 160 mm)
4,5
9
CAD 30
CAD 40
6
6
65
65
1,1(1,5)
1,5(2)
2,8
3,6
1500
1500
61
94
46
74
11(15)
15(20)
22(30)
21,5
29
41,5
35
50
63
157
195
324
69
69
149
4200
4700
4100
1
1
2
12,5
19
27
Noise ratings for
blowers and fans
The noise measurements were
made with a long duct connected to
the blower outlet side, while the
blower operates at maximum con-
veying capacity, but while no materi-
al was conveyed by the blowers.
Sound
Blower
power LwA
distance of 1 m.
[db]
TRL 20
92
TRL 40
92
TRL 55
105
TRL 75
99
TRL 100
101
TRL 150
109
TRL 200
-
TRL 300
107
TRL 500
108
37(50)
69,5
100
468
201
4300
3
46
Sound pres-
sure in a
LpA [db]
83
82
91
85
90
97
-
93
93