Servicing and maintenance
The spark plug (7) is removed using an 11mm wrench (right-handed thread).
The injector is removed using a 7mm hexagonal key.
Do not use solvents to clean the plastic parts of the handle, hot, soapy water will suffice.
More major servicing and repair must only be carried out by an authorised repairer.
Guarantees
Our torches come with a two year guarantee
Spare parts
Designation
Injector Ø11mm
Injector Ø13mm and Ø14mm
Injector Ø18mm and Gyroflam®
Injector Ø22mm
Piezo handle spark plug
Piezo handle coupling
Burners
Désignation
Needlepoint Burner Ø11mm
Needlepoint Burner Ø14mm
Needlepoint Burner Ø18mm
Needlepoint Burner Ø22mm
Turbojet® Burner Ø13mm
Turbojet® Burner Ø18mm
Turbojet® Burner Ø22mm
Gyroflam® Burner
Troubleshooting
Weak flame
Diagnosis:
The gas cylinder is empty
The injector is stoppered
The cylinder or torch valves are insufficiently open
The pressure gauge is incorrectly adjusted.
The torch will not light
Diagnosis:
Defective spark plug
The ignition system is defective
Code
529001
529002
529003
529004
529007
529008
Type de gaz
Code
Butane or Propane
520011
Butane or Propane
520012
Butane or Propane
520013
Propane
520014
Propane
520020
Propane
520021
Propane
520022
Propane
520025
Remedy:
Replace or fill in the cylinder
Replace the injector
Open to the maximum extent
Check the gauge setting.
Remedy:
Replace the spark plug
Send the torch to an authorised repairer
7