Maintenance; Maintenance Of Jaws; Diagnostics And Problem-Solving; The Jaws Do Not Slide Correctly Into The Press - Virax Viper P10 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3

Maintenance

Maintenance of jaws

Regularly check that the jaws are in good condition. Check that the jaws close well at their
ends.
Clean the jaws using a dry rag or a metal brush.
Keep the press fitting profile clean.
Lubricate the spindles of press fitting jaws.

Diagnostics and problem-solving

The jaws do not slide correctly into the press

Check that the pad-rollers are as far back as they will go. If they are not, press on the return
trigger until the rollers have entered fully into the body of the press fitting machine.

Guarantees

All our press fitting machines in the Viper range are guaranteed for 2 years. Press fitting jaws
sold by Virax are guaranteed for 5 years except for the profile.

Technical form

For Per or Pex, multi-layer pipes of Ø 12 to Ø 63mm and copper, stainless steel and steel pipes
of Ø 12 to Ø 54 mm.
Press
Axial pushing force: 32kN
Travel: 40 mm
Dimensions: 515 x 92 x 130
Return trigger for pad-rollers
Pumping handle
Jaws
33HRC very high resistance steel
15

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

2530 10

Table des Matières