Installation
4.4.2
Adjustment of limit switches
CAUTION
Risk of damage to unit by incorrect limit switch adjustment.
• Before adjusting the limit switches, the piston rod must be moved several
centimetres away from the position to be set.
Factory setting:
The limit switches have been preset to the dimensions defined in the order con-
firmation.
If any other dimensions are required, proceed as described below.
The two limit switch setting screws are located on the cover of the piston side of
the device.
1.
Move the piston rod a few centimetres away from the targeted limit switch
position.
2.
Adjust the limit switch (+/-).
3.
Move the drive back to the limit switch.
4.
Repeat the process until the desired dimension is reached.
Fig. 4
1
2
3
22
Lid with setting screws
Setting screw min (limit position „piston retracted")
Setting screw max (limit position „piston ejected")
Housing cover