Using The Cooler - Dometic WAECO Coolfreeze CF 80 Manuel D'utilisation

Masquer les pouces Voir aussi pour WAECO Coolfreeze CF 80:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 40
Operation
In "HIGH" mode, the battery monitor responds faster than at the
levels "LOW" and "MED" (see the following table).
Battery monitor mode
Switch-off voltage at 12 V
Restart voltage at 12 V
Switch-off voltage at 24 V
Restart voltage at 24 V
This is how to select the battery monitor mode:
➤ Switch on the cooler.
➤ Press the "SET" button (fig. 2 4, page 3) three times.
➤ Use the "UP +" (fig. 2 6, page 3) and "DOWN -" (fig. 2 7,
page 3) buttons to select the battery monitor mode.
✓ The selected mode then appears in the display for a few sec-
onds. The display flashes several times before it returns to the
current temperature.
NOTE
I
When the cooler is supplied by the starter battery, select the battery
monitor mode "HIGH". If the cooler is connected to a supply battery,
the battery monitor mode "LOW" will suffice.
If you wish to operate the cooler from the AC mains, set the battery
monitor to the "LOW" position.
6.5

Using the cooler

NOTICE! Danger of overheating!
A
Ensure at all times that there is sufficient ventilation so that the
heat that generated during operation can dissipate. Ensure that
the ventilation slots are not covered. Make sure that the device
is sufficiently far away from walls and other objects so that the
air can circulate.
➤ Place the cooler on a firm foundation.
Make sure that the ventilation slots are not covered and that the
heated air can dissipate.
➤ Close the cooler, see "Connecting the cooler" on page 31.
34
LOW
MED
10.1 V
11.4 V
11.1 V
12.2 V
21.5 V
24.1 V
23.0 V
25.3 V
CoolFreeze
HIGH
11.8 V
12.6 V
24.6 V
26.2 V
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Waeco coolfreeze cf 110Waeco cf80Waeco cf110

Table des Matières