UK
Table of Controller Parameters
The operating parameters of this appliance have been preset for optimum performance and to maximise
the life of the appliance.
Display
E1
E2
E3
E4
Temperature buffer time delay
E5
E6
F1
F2
F3
F4
Should any parameter need adjusting:
Press and hold the
1.
Press the
or
2.
Press the
button to store the new value and cycle to the next parameter.
3.
Note: The controller times out after ten seconds if no buttons are pressed for ten
seconds.
Manual Defrost
Press and hold the
Storing Food
To get the best results from your POLAR appliance, follow these instructions:
•
Only store foodstuffs in the appliance when it has reached the correct operating temperature.
•
Do not place uncovered hot food or liquid inside the appliance.
•
Wrap or cover food where possible.
•
Do not obstruct the fans/vents inside the appliance.
•
Avoid opening the doors for prolonged periods of time.
3
Parameter
Lower set temperature
Upper set temperature
Temperature buffer
Fixed parameter
Fixed parameter
Defrost period
Defrost interval
Defrost temperature
Centigrade/Fahrenheit
button for six seconds. The'E1' parameter is displayed.
buttons until the required value is displayed.
button for 6 seconds to begin automatic defrost. The Defrost light illuminates.
Preset Value
2ºC
6ºC
4ºC
3
0
00
DO NOT CHANGE-
25 minutes
6 hours
20ºC
ºC
Range
-20 to 2ºC
2 to 45ºC
1-10ºC
0-10 minutes
DO NOT CHANGE
1-60 minutes
1-24 hours
0-22ºC
ºC/ºF