SETTINGS

Š DATE/TIME
Š LANGUAGE
Š DEGREES

DISPLAY

The "DISPLAY" menu allows:
Š Regulation of DISPLAY contrast
Š Activation/Deactivation of backlight.
Š Enabling/disabling of acoustic signal.
Š Setting of the timer to turn o the Display backlight.
Š Setting of the timer to turn o the Display (sleep mode).
To set: OK > SETTINGS > DISPLAY.

STAND BY

The STAND BY function is used if the stove needs to be turned o immediately instead of a power modulation.
To set: OK > SETTINGS> STAND BY.
STAND BY FUNCTION SET TO ON
If the STAND BY function is enabled (ON) and the ambient temperature exceeds the SET THERMOSTAT + DELTA-T OFF value, then the stove
switches o after a preset factory delay, and STAND BY will be displayed on the screen.
When the ambient temperature is less than SET THERMOSTAT - DELTA-T ON and after a certain cooling time, the stove ignites again.
STAND BY FUNCTION SET TO OFF FACTORY SETTING
When the STAND BY function is not enabled (OFF), if the stove exceeds the set ambient temperature, it will switch to the minimum power
level, modulating and displaying MODULATION on the screen. When the room temperature is lower than the SET THERMOSTAT the stove
will restart at the set power and WORK will be displayed on the screen.

OPERATION WITH ADDITIONAL THERMOSTAT OPTIONAL

STAND BY FUNCTION SET TO OFF FACTORY SETTING
When the STAND BY function is not activated (OFF), if the stove exceeds the room temperature set on the supplementary thermostat (open
contact), it switches to the minimum power level and displays MODULATION on the screen. When the ambient temperature is lower than the
set value on the additional thermostat (closed contact), the stove will resume operation at the set power, and WORK will be displayed on the
screen.
STAND BY FUNCTION SET TO ON
If the STAND BY function is activated (ON), when the room temperature set on the supplementary thermostat is reached (open contact), the
stove will switch o after a pre-set default delay period, and STAND BY will be displayed on the screen.
When the ambient temperature is less than the set temperature on the additional thermostat (closed contact), and after a certain cooling time,
the stove ignites again.
FOR CORRECT OPERATION, THE SET THERMOSTAT MUST BE SET TO LOW TA.
> SEE THE INSTALLATION CHAPTER SUPPLEMENTARY THERMOSTAT
SEE CHAPTER: COMMISSIONING SETTINGS.