AIR DUCTING FEATURES INSERTO 850 ELITE

The model is tted with two independent air ducting outlets. The pipe used for ducting the hot air must have an internal diameter of 80 mm
and it must also be insulated or at least be protected against heat dispersion.
Air ducting 1 - 2 are enabled by factory default.
Features:
Š diameter of air ducting outlet: 2x80 mm
Š maximum recommended air ducting length 8 m
Š temperature controlled air ducting
Š Speed regulation can be set in 2 modes: AUTO, COMFORT

FACTORY DEFAULT OPERATION IN AIR DUCTING MODE

Air ducting 1 and 2 are always in request by factory default (jumpers on Z1 and Z2 present), and follow the stove settings.
- No settings necessary.

OPERATION IN AIR DUCTING WITH THERMOSTAT OR PROBE OPTIONAL

The stove is tted with two independent motors for air ducting. The connection of an external thermostat or temperature probe (NTC 10K)
in inputs 1 and 2, located in the rear part of the stove, makes it possible to control the air ducting motor independently of the stove.
Su ce it to connect the thermostat/temperature probe and set the desired temperature.
For information on air ducting settings see chapter:" MENU AIR DUCTING"
WITH AMBIENT THERMOSTAT OPTIONAL
Remove the jumper on 1 and connect the ambient thermostat in the room that needs to be temperature-controlled through air ducting 1.
2 control modes:
OPERATION IN AIR DUCTING WITH AMBIENT THERMOSTAT OPTIONAL
SET con gured to AUTO
(the temperature setting is not visible)
SET con gured to COMFORT
(the temperature setting is not visible)
Once the speci c activation threshold has been reached and exceeded, at temperature
to be satis ed (CLOSED CONTACT) the air ducting motor will follow the stove settings.
When the temperature set on the thermostat is reached (OPEN CONTACT), the air
ducting motor will switch to minimum and then follow the stove settings again when
there is a new request.
Once the speci c activation threshold has been reached and exceeded, at temperature
to be satis ed (CLOSED CONTACT) the air ducting motor will follow the stove settings
but at a lower speed than in SET AUTO for increased acoustic/ambient comfort.
When the temperature set on the thermostat is reached (OPEN CONTACT), the air
ducting motor will switch to minimum and then follow the stove settings again, but
at a lower speed when there is a new request.
SAME OPERATING SETTINGS FOR AIR DUCTING 2 MOTOR
ENGLISH
Z2
I
Z1
57