Electromagnetic compatibility (EMC)
Emitted interference
Limit class
B to EN 55022 = CISPR 22
Interference
"2 kV
immunity on signal
lines
Interference immu-
"6 kV
nity against
discharging of static
"8 kV
electricity
Noise immunity to
10 V/m 80 to 1000 MHz and 1,4 to 2 GHz,
high-frequency
80 % AM 1 kHz (to IEC 61000-4-3)
radiation
1 V/m 2 to 2,7 GHz, 80 % AM 1 kHz
(to IEC 61000-4-3)
HF current
10 V 10 kHz to 80 Mhz, 80 % AM 1 kHz
(to IEC 61000-4-6)
Climatic conditions
Temperature
Tested to DIN IEC 60068-2-1, DIN IEC
60068-2-2
operation
storage/
shipping
Relative humidity
Tested to DIN IEC 60068-2-3, DIN IEC
60068-2-78
operation
storage/
shipping
PC/TS Adapter
A5E00078070-03
PC/TS Adapter
Technical Specifications
(to IEC 61000-4-4; Burst)
Contact discharge
(to IEC 61000-4-2; ESD)
Air discharge
(to IEC 61000-4-2; ESD)
"0 °C to +60 °C
(rate of temperature change
max. 10 °C/h)
-40 °C to +70 °C
(rate of temperature change
max. 20 °C/h)
5 % to 85 % at 30 °C
(no condensation)
5 % to 93 % at 40 °C
(no condensation)