Wiring diagrams for 3-wire
network 127 V / 220 V
Photo cell
black
red
L
127 V
white
N
Photo cell
black
L
220 V
white
L
Photo cell
black
red
L
127 V
white
N
L
Photo cell
black
red
L
220 V
white
L
N
Wiring diagrams for 3-wire network
230 V / 400 V
Photo cell
black
L
230 V
white
N
6
Explosion-protected photo cell Ex d, GHG 640 9601 P....
1

Technical Data

1.1
Photo cell
EU-Type Examination Certificate:
Marking acc. to 2014/34/EU and
IECEx Certificate of Conformity:
Category of application and
127 V
Rated voltage:
Load
Rated current:
Switching capacity:
Permissible power dissipation:
Permissible ambient temperature:
(Other temperatures possible with special versions.)
Perm.ambient temperature in original packing: -40° C to +80° C
Protection category acc. to IEC/EN 60529:
Insulation class acc. to EN/IEC 61140:
Screw-in thread:
red
220 V
Test torque:
Load
Weight:
Cross section connecting cable (LM125/150°C): 16 AWG
2

Safety instructions

Target group:
For skilled electricians and suitable
qualified, instructed personnel in
220 V
accordance with national legislation, including
Load
the relevant standards and, where applicable,
in acc. with IEC/EN 60079-14 on electrical
apparatus for explosive atmospheres.
The photo-cells are not suitable for zone 0 and
zone 20, 21 and 22 hazardous areas.
The temperature class and type of protection
stated on the apparatus shall be observed.
Prior to being put into operation, the pho-
to-cell shall be checked in accordance with the
instructions as per section 6.
The national safety rules and regulations for
127 V
the prevention of accidents, as well as the
Load
safety instructions included in these operating
instructions, are set in italics, and shall be
observed!
red
230 V
Load
standard series EN 60079:
standard series IEC 60079:
GHG 640 9601 P0004
GHG 640 9601 P0005
M32 x 1,5
1" NPT
Sira 17 ATEX 1219 X
II 2 G Ex db IIC T6 Gb
IECEx CSA 17.0016 X
Ex db IIC T6 Gb
100 V AC to 260 V AC 50/60 Hz
max. 10 A
1000 W (1800 VA)
< 1 W
-40° C to +70° C
IP 66 (standard version)
I - is device fulfil this requirement
M32 x 1,5
1" NPT
min. 3.0 Nm
max. 6.0 Nm
Wrench hard
approx. 0.25 kg
3

Conformity with standards

The apparatus are conform to the standards
specified in the EC-Declaration of conformity,
enclosed separately.
References to standards and directives in these
operating instructions always relate to the
latest version. Other additions (e.g. details
relating to the year) shall be observed.
4

Field of application

The photo-cells are suitable for use in zone 1,
and 2 hazardous areas acc. to
IEC/EN 60079-10-1.
The photocell is to be installed in a housing,
performed by a protection to IEC/EN 60079-0
(e.g .: flameproof or increased safety), provided.
The enclosure materials employed, including
the exterior metal parts, are made of high-quali-
ty materials which ensure a corrosion
protection and resistance to chemical
substances corresponding to the requirements
in a "normal industrial atmosphere":
- aluminium
In case of use in an extremely aggressive
atmosphere, you can obtain information
concerning the chemical resistance of the
materials used from your Cooper Crouse-Hinds
branch.
GB

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ghg 640 9601 p0004Ghg 640 9601 p0005

Table des Matières