Cleaning; Storage And Conservation; Checks And Maintenance; For Your Safety During Routine Inspection - DRENO Compatta PRO Manuel D'utilisation Et D'entretien

Masquer les pouces Voir aussi pour Compatta PRO:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

9 .3 Cleaning

If the pump operates in liquids with suspended material, at the end of use it is necessary to run the pump for
several minutes in clean water. The impurities (mud, stones, etc) should be eliminated to avoid any dry impuri-
ties blocking the impeller and seal, thus preventing the electric pump to function correctly.
9.4 Storage and conservation
If the pump is stored in a storeroom it is compulsory to:
• Store away from excessive heat and cold (acceptable range: 0÷40 °C)
• Position vertically, taking great care to ensure its stability to avoid rolling and falling.
During the storage period, it is advisable to manually rotate the impeller occasionally, for GM-GT rotating at
least every two months, wearing individual safety gloves, to prevent the seals sticking. In any case, before
using the pump again always ensure the impeller shaft rotates freely and the motor electric insulation exceeds
5Mohm.
Checking the oil lubrication level should only be carried out outside the pump operating areas. The oil level must
be below the access hole by 1÷1.5 cm.
To top up or replace the oil, position the pump level. The oil may be also checked by non Dreno personnel on
condition said personnel are skilled. Skilled personnel are persons competent in the maintenance of electrome-
chanical equipment and possess at least 5 years relevant experience.
If necessary to top up or replace the oil, always use Q8 WF 15 or an equivalent product. Replace the oil every
4.000 operating hours (GX, AT-AM 50/2/110 C.225-226 solely)

10 . Checks and maintenance

10 .1 For your safety during routine inspection

• Check the electric supply is disconnected and that the pump cannot restart itself, even
accidentally, before starting work on the pump.
• To avoid biological contamination, ensure the pump is cleaned thoroughly with water and
non-aggressive detergents that do not compromise the integrity of the pump itself.
• The electric pump should only be disassembled by qualified DRENO POMPE engi-
neers, taking care to handle the parts wearing safety gloves.
• Before any maintenance intervention, make sure to operate in a non-hazardous area
(safe area)

10 .2 Recommended checks

• Should the user detect the presence of anomalous pump noises, (for example, humming)
it is essential to contact Dreno Pompe Technical Assistance, do not use the pump until
the cause has been identified, which may be caused by a broken or worn bearing.
• Should the user detect an abnormally high operating temperature it is essential to con-
tact Dreno Pompe Technical Assistance, do not use the pump until the cause has been
identified, which may be caused by a broken or worn bearing, or seizure of a seal.
Periodic checks and preventive maintenance guarantee the safest pump operation over time.
When the pump is newly installed or when mechanical parts are replaced, it is advisable to visually inspect
the pump after one working week.
The pump should be regularly inspected after 2,000 working hours or at least once a year.
Frequent checks are necessary for demanding operating conditions or occasional use.
A routine check should be made on the following points:
• Visually check there are no seepages by the cable inlet point.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
- 32
In the event the cable or sheath are swollen or damaged, it must be replaced by the manufacturer, its support
service or qualified personnel in order to avoid any risk.
Check the level and quality of the oil in the sump, oil filling is complete when, with the electric pump laid down on
one side, the level is 1-1.5 cm below the oil filler cap (GX, AT-AM 50/2/110 C.225-226 solely).

10 .3 Motor insulation check

At least once a year or in any case after 4,000 operating hours it is compulsory to check motor isolation.
Measure the end of the cable (detached from the control board) using a megaohmeter.
The test voltage must comply with applicable reference standard.
To carry out the test, it is compulsory to disconnect the motor cable and measure the winding towards the
mass, connecting all the winding ends.
The winding resistance towards the mass must be higher than 5 MΩ,
failing which it is necessary to take two measurements, one for the cable and the other for the motor.
If the cable isolation value is lower than 5MΩ, this means the cable is damaged.
If the motor has very low insulation values, this means there is a winding insulation failure.

11 . Spare Part List

The spareparts list and related purchases, are available on-line at Dreno Part Selector though our web site
www .drenopompe .it, or contact us at info@drenopompe.it.

12 . Impeller replacing

12 .1 GX
The following operations should only be carried out by qualified DRENO POMPE engineers.
To replace the impeller, carry out these operations in sequence.
A) Unscrew the 3 socket head screws that connect the closing plate with base to body pump.
B) Now, extract the closing plate with base from pump body.
C) Wearing safety gloves hold the rotating knife still; unscrew the hexagonal head screw connecting the
motor shaft.
D) By unscrewing this screw, you can easily remove the impeller with the rotating knife.
Before fitting a new impeller, pay attention that the end of the shaft is clean and has no imperfections.
12 .2 AM-AT 50/2/110 C .225-226
The following operations should only be carried out by qualified DRENO POMPE engineers.
To replace the impeller, carry out these operations in sequence.
A) Unscrew the 3 socket head screws that connect the supporting tripod with base to body pump.
B) Now, extract the supporting tripod from body pump.
C) Using a wrench, unscrew the self-locking nut that fastens the impeller.
D) The impeller should now easily remove from the motor shaft.
Before fitting a new impeller, pay attention that the end of the shaft is clean and has no imperfections.
12 .3 Compatta PRO - Alpha V PRO - DNB 65-EX
The following operations should only be carried out by qualified DRENO POMPE engineers.
To replace the impeller, carry out these operations in sequence.
A) Unscrew the 3 socket head screws that connect the body pump with the motor casing.
B) Now, extract the body pump from the motor casing.
C) Using a wrench, unscrew the self-locking nut that fastens the impeller.
D) The impeller should now easily remove from the motor shaft.
Before fitting a new impeller, pay attention that the end of the shaft is clean and has no imperfections.
12 .4 BIC PRO
The following operations should only be carried out by qualified DRENO POMPE engineers.
To replace the impeller, carry out these operations in sequence.
- 33

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Alpha v proBic proAm-atGxDna -exDnb -ex

Table des Matières