Connection And Electrical Data - Wilo Drain LP 40 Notice De Montage Et De Mise En Service

Masquer les pouces Voir aussi pour Drain LP 40:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English

1.2.2 Connection and electrical data

Power supply
Mains frequency
System of protection
Isolation class
Operating mode
Capacity max.
Speed max.
max. power input
Admission output P1
Motor-output P2
Conveying capacity
Delivery head max
Suction head
Nominal width delivery side
Nominal width suction side
Temperature range of the flow medium:
1.2.3 suction time
The duration of the suction process of the LP40 pump depends on the suction depth. The diagram
below shows the process duration in dependence on the depth. The mentioned time values are aver-
age values, depending from the conditions of use, they may deviate, for example by using a suction-
hose.
7
6
5
4
3
2
1
0
0
10
Ansaugzeit
Suction time
5
10
Zeit t [min]
Time [min]
1 ~ 230 V, ±10%
50 Hz
IP 44
B
S1 continuous operation
9μF, 450V
max. 2900 ¹/min (50 Hz)
see rating plate
500W
400W
see rating plate
see rating plate
6m
40mm, 1½ "
40mm, 1½ "
0 up to +35°C
Depth [m]
1,0
2,0
3,0
4,0
5,0
6,0
15
Time [min] ca.
1
2
4
6
9
10

Publicité

Table des Matières
loading

Table des Matières