SPECIFICATIONS D'INSTALLATION
HUMIDAIRE A PETROLE HU-60-1265
N°.
DESCRIPTION
1
ALIMENTATION TRIPHASEE
HUMIDAIRE
2
TELECOMMANDE HUMIDAIRE,
CABLE TELECOMMANDE 120VAC
3
TELECOMMANDE HUMIDAIRE,
SIGNAUX BAS NIVEAU
4
DETECTEUR PRESENCE FIBRE
(POUR LES TREMIES COTON-
GRAINE, LE RACCORDEMENT SE
FAIT SUR LA PLATINE A RELAIS)
5
ALIMENTATION CARBURANT
HUMIDAIRE
6
ALIMENTATION AIR COMPRIME
HUMIDAIRE
5
ALIMENTATION GAZ HUMIDAIRE
(MODELE MIXTE GAZ-PETROLE)
6
ALIMENTATION EAU HUMIDAIRE
7
EVACUATION EAU HUMIDAIRE
8
MODULE DE DIAGNOSTIC REF.
20050 (OPTIONNEL)
* FOURNIS AVEC L'HUMIDAIRE HU-60-1265
© SAMUEL JACKSON, INCORPORATED 2003 ALL RIGHTS RESERVED – TOUS DROITS RESERVES
PAGE 31 de 89 HUMIDAIRE A PETROLE HU-60-1265
RACCORDEMENTS ET NOTES
DEPUIS LE POINT D'ALIMENTATION VERS
L'HUMIDAIRE. 3P+T 380VAC, 415VAC 50Hz ou
480VAC 60Hz, 8 HP – 6 kW, CABLE 4 X 6 mm
CONTACTEURS ET TRANSFORMATEUR POUR
TELECOMMANDE 120 VAC INCLUS DANS
L'HUMIDAIRE.
DEPUIS LE COFFRET DE L'HUMIDAIRE VERS
LA COMMANDE A DISTANCE (PUPITRE
EGRENAGE), CABLE 12 X 1.5 mm
DEPUIS LE COFFRET DE L'HUMIDAIRE VERS
LA COMMANDE A DISTANCE (PUPITRE
EGRENAGE), 2 CABLES BLINDES 2 X 1 mm
PEUVENT CHEMINER AVEC LES CABLES
THERMOCOUPLES. *
DE L'HUMIDAIRE VERS LE DETECTEUR DE
PRESENCE FIBRE SITUE SOUS LE
CONDENSEUR GENERAL, CABLE 4 X 1.5 mm
TUYAU 1/2"
PETROLE ou GAZOLE
TUYAU 3/8" – DEBIT 6 SCFM (170 l/min)
100 PSI, 6.8 BAR
TUYAU GAZ 1". GAZ NATUREL OU PROPANE.
5 A 15 PSI, 0.3 A 1.4 BAR. NE PAS ENTERRER.
TUYAU ALIMENTATION 3/4", 20 PSI - 1.4 BAR
MIN.
TUYAU EVACUATION PVC 2", 4000 LITRES
PAR 24 HEURES ENVIRON.
DEPUIS LE COFFRET DE COMMANDE
LOCALE:
2 PAIRES BLINDEES, TORSADEES MISE A LA
TERRE DU BLINDAGE COTE COFFRET * ET
2
CABLE 4 X 1.5 mm
. PEUVENT CHEMINER
AVEC LES CABLES DE TELECOMMANDE BAS
NIVEAU.
DEPUIS LA COMMANDE A DISTANCE REF.
20500: CABLE 2 X 1.5 mm
2
.
2
.
2
.
2
.
2
.