TABLE "B" - LOGIC MENU - (logic)
Logic
Default Definition
OFF
Automatic Closing Time
tca
OFF
Opening Impulse lock
Ibl open
OFF
Impulse lock TCA
ibl TCA
OFF
3-step logic
3 step
OFF
Pre alarm
pre-alar
OFF
Photocells on opening
photc. open
OFF
Rapid closing
fast cls
OFF
Photocell test
test phot
OFF
Electric edge test
test BAR
OFF
Fixed code
fixed code
Radio transmitter
ON
radio prog
programming
OFF
1 Active Motor
1
ot. on
Gate-open or 2nd radio
OFF
sca-2ch
channel warning light
OFF
Reversing motion
change
ot.
Closing limit switch
press. svc
ON
(special dip 1*)
pressure
*Refer for universal handheld programmer.
16 - HIDE SW
INSTALLATION MANUAL
Cross out
Description
setting
used
ON
Activates automatic closing
OFF
Excludes automatic closing
ON
The Start impulse has no effect during the opening phase.
OFF
The Start impulse becomes effective during the opening phase.
ON
The Start impulse has no effect during the TCA dwell period.
OFF
The Start impulse becomes effective during the TCA dwell period.
ON
Enables 3-step logic.
Disables 3-step logic activating the
OFF
4-step logic.
ON
The blinker comes on about 3 seconds before the motor starts.
OFF
The blinker comes on at the same time as the motor starts.
In case of obscuring, this excludes photocell operation on opening. During the closing phase, it
ON
immediately reverses the motion.
In case of obscuring, the photocells are active both on opening and on closing. When a pho-
OFF
tocell is obscured on closing, it reverses the motion only after the photocell is disengaged.
Closes 3s after the photocells are cleared before waiting for the set TCA to elapse.
ON
Command not entered.
OFF
ON
Activates photocell check (Fig. J)
OFF
Deactivates photocell check
Activates electric edge check (Fig. J)
ON
OFF
Deactivates electric edge check
The receiver is configured for operation in fixed-code mode, see paragraph on "Radio Trans-
ON
mitter Cloning".
The receiver is configured for operation in rolling-code mode, see paragraph on "Radio
OFF
Transmitter Cloning".
This enables transmitter storage via radio:
1 – First press the hidden key and then the normal key (T1, T2, T3 or T4) of a transmitter already
memorised in standard mode by means of the radio menu.
2 – Within 10s press the hidden key and the normal key (T1, T2, T3 or T4) of a transmitter to
be memorised.
ON
The receiver exits the programming mode after 10s, other new transmitters can be entered
before the end of this time.
This mode does not require access to the control panel.
IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
This disables transmitter storage via radio.
OFF
The transmitters can only be memorised using the appropriate Radio menu.
IMPORTANT: Disables the automatic addition of new transmitters, clones and replays..
ON
Only motor 2 activated (1 leaf ).
OFF
Both motors are activated (2 leaves).
The output between terminals 21 and 22 is configured as Gate-open warning light, in this case
ON
the 2nd radio channel controls pedestrian opening.
OFF
The output between terminals 21 and 22 is configured as 2nd radio channel.
ON
Opens in the other direction depending on how motors are installed. (Fig. M)
OFF
To be used when a closing backstop is present.
This function activates leaf pressure on the backstop, without this being considered as an
obstacle by the ampere-stop sensor.
ON
Therefore the rod continues its stroke for another 2s, after intercepting the closing limit switch
or as far as the backstop. This way, by slightly anticipating closing limit switch activation, the
leaves will come to a perfect halt against the end stop plates (Fig. K Rif. A).
Movement is exclusively stopped by closing limit switch activation, in this case you must
OFF
proceed to a precise setting of closing limit switch activation (Fig. K Rif. B).
A start impulse has the following effects:
3 steps
closed
opens
on closing
open
closes
on opening
stop + TCA
after stop
opens
4 steps
opens
stop
closes
stop + TCA
opens