Specification
Measurement:
Accuracy:
Open circuit voltage:
Test current:
Zero offset at probe tips:
Lead resistance zeroing:
Bleeper:
Measurement:
Accuracy:
Open circuit voltage:
Short circuit current:
Analogue Scale
0 to 500 V Range
0 to 50 V Range
Default Voltmeter
Operates at >25 volts a.c. or d.c. on any range except OFF and Battery check. Reverse polarity
d.c. will cause '-dc' to appear in the display.
15
Continuity (BM80/2 & BM81/2 only)
0,01 Ω to 99,9 Ω (0 to 50 Ω on analogue scale)
± 2% ± 2 digits
5 V ± 1 V
205 mA ± 5 mA (0 - 10 Ω)
0,10 Ω typical
Up to 9,99 Ω
Operates at less than 5 Ω (approx).
Resistance
0,1 kΩ to 100 kΩ (0 to 10 MΩ on analogue scale)
± 3% ± 2 digits
5 V ±1 V
20 µA ± 5 µA
Voltage
Measurement
0 to 450 V d.c. or a.c. (50/60 Hz)
450 to 600 V d.c. or a.c. (50/60 Hz)
0 to 450 V 400 Hz a.c.
0 to 50,0 V d.c. or a.c. (50/60 Hz)
Accuracy(>1 V)
± 1% ±1 digit
± 2% ±1 digit
± 5% ±2 digits
± 2% ±2 digits