1.0 TECHNICAL DATA / ELECTRICAL DATA

TECHNICAL DATA
Marking acc. to 94/9/EC
EC type examination
certification
Approval of the production
quality assurance
Type of lamps
ELECTRICAL DATA
Rated voltage
Rated frequency
Power factor cos
Rated lamp power
Degree of protection acc. to
IEC/EN60529
Insulation class acc. to
IEC/EN61140
Permissible ambient
temperature
Perm. storage temperature in
original packing
Cable entries

2.0 SAFETY INSTRUCTIONS

For skilled electricians and
!
qualified personnel in
accordance with national
legislation, including the relevant
standards and where applicable, in
accordance with IEC/EN60079-17
on electrical apparatus for
explosive atmospheres.
The national safety rules and
regulations for prevention of
accidents and the following safety
instructions, which are marked with
( ) in these operating instructions, must be observed.
!
- The luminaire must not be operated in Zone 0, 1, or Zone 20
hazardous areas.
- When using in Zone 21 or Zone 22, the requirements of IEC/
EN60079-14 relating to temperature must be observed.
The indicated surface temperatures in Table 1 are not
related to layer above 5mm thickness.
IF 1599
07/09
Ex nR II T...Gc(*)
Ex t IIIC T...°C(*) Db IP66
(*)see Table 1
LCIE 09 ATEX 1002
LCIE 09 ATEX 3008
Baseefa ATEX 5952
High Pressure Sodium (HPS)
Metal Halide (MH)
220V, 230V, 240VAC
50Hz, 60Hz
0.9
70W to 250W
IP66
I
-45˚C to +55˚C
-45˚C to +60˚C
M20 x 1.5 up to M32 x 1.5
NPT 1⁄2" up to NPT 1 1⁄2"
LEGEND
!
SAFETY
WARNING
NOTE
i
INFORMATION
Copyright © 2009, Cooper Industries, Inc.
- The technical data indicated on the luminaire is to be ob-
served.
- The luminaire shall be operated as intended and only in
undamaged and perfect condition.
- Multiple, short-term switching must be observed.
- Only original Cooper Crouse-Hinds parts may be used as
replacements and for repairs.
- Repairs may only be carried out by Cooper Crouse-Hinds or
a qualified electrician.
- Do not keep these operating instructions inside the lumi-
naire during operation.
- If the cable glands distributed with the luminaire will be
replaced in the field, the restricted breathing (nR) proper-
ties must be checked.
- Before opening, electrical power to the luminaire must be
turned off for at least 10 minutes.
- Keep tightly closed when in operation.
Do not install where the marked operating temperature exceeds
the ignition temperature of the hazardous atmosphere. Do not
operate in ambient temperatures above those indicated on the
luminaire nameplate.

3.0 CONFORMITY WITH STANDARDS

It has been designed, manufactured, and tested according to ISO
9001.
The apparatus conforms to the standards specified in the ECDeclara-
tion of Conformity. It was developed, manufactured, and tested
in accordance with the latest technology.

4.0 FIELD OF APPLICATION

The luminaire is intended for use in potentially explosive atmospheres
(Zone 2 according to IEC/EN60079-10-1 and Zone 21 and Zone 22 in
accordance with IEC/EN60079-10-2).
The enclosure materials used, including any external metal parts, are
high quality materials that ensure corrosion resistance and resistance
to chemical substances according to the requirements for use in a
"normal" industrial atmosphere.
- Copper-free aluminum.
- Stainless steel.
- Epoxy powder finish.
In case of use in an extremely aggressive atmosphere, please refer to
manufacturer.

5.0 APPLICATION / PROPERTIES

The luminaire can be used inside or outside to light areas with
potentially explosive atmospheres.

6.0 INSTALLATION

6.1 GENERAL

For mounting and operation, the respective national regulations
(IEC/EN60079-14) as well as the general rules of engineering must be
observed.