7.6 Key switch connection
A key switch can be connected to the terminal clamps 10 and 11. Thus, it is
possible to arm or disarm the alarm system with this switch.
1
2
3
4
The alarm system is disarmed when the connected contact is closed. The alarm
system is armed (after the end of the exit delay = 60 seconds) when the contact
is opened.
Always observe that the slider on the front is in the "HOME" or
"AWAY" position if the device is to be armed or disarmed with an
external key switch.
7.7 External status LED connection
An additional status LED be connected to the terminal clamps 5 (+) and 12. This
makes it possible to recognise the alarm system's operating state from another
site.
1
2
3
4
The function of the external status LED is identical with the function of the
"EXIT" status LED on the alarm system's front.
40
5
6
7
8
1K
+
5
6
7
8
KEYSWITCH
-
9
10
11
12
LED
9
10
11
12