MWD BPC-H / MWD BPC-HU
5.2.2 Connect motion detector to door controller with the control unit TST UTH
If the TST UTH control unit is also connected to the door controller, the yellow switch on the door
controller board must be changed. The terminating resistor in the TST UTH control unit is permanently
installed.
1. Pull down the yellow switch (Figure 5).
In position ON no TST UTH is used (factory
setting).
2. Connect the first motion detector and the
TST UTH to the door controller (Figure 6).
3. Test the operational readiness of the motion
detector and the control unit TST UTH.

5.3 Display during operation

The motion detector has two LEDs that indicate the current status of the motion detector. The following LED
signals are possible:
Table 2: LED display during operation
State of LED
yellow
OFF
Flashes 1x/sec.
ON
ON
X
OFF
flashes 4 x/sec.
Flashes 2x/second synchronously
FEIG ELECTRONIC GmbH
Comissioning
red
No power supply
OFF
Ready / no object detected
ON
Channel 1 and 2: object detected
X
Channel 1: object detected
ON
Channel 2: object detected
Bus connection is incorrect or no communication to the door
controller
Motion detector aktivated for configuration
37/74
Figure 5: Switch to control unit TST UTH
Figure 6: Connecting to the door controller with
control unit TST UTH
Description
MWD_BPC-H-HU_ver4_Manual_rev0_mul