Comissioning; Connecting The Motion Detector; Connecting To The Door Controller - FEIG Electronic MWD BPC-H Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
5

Comissioning

Up to four motion detectors may be connected.
For specifications of the CAN interface (max. cable length, cable specification, etc.), refer to the
instructions of the door controller used!

5.1 Connecting the motion detector

The following example shows a bus with four motion detectors.
1. Connect the motion detector cable with one
another using the snap-in connectors
(Figure 2, Pos. 1-4).
2. Attach the accompanying plug on the open snap-
in connector of the last motion detector
(Figure 2, Pos. 4) with terminator.

5.2 Connecting to the door controller

he system must be disconnected from the power supply during the
T
CAUTION
installation.
5.2.1 Connect motion detector to door controller
1. Connect the wires of the CAN connection cable
to the terminal X28B as follows:
G
-> blue
CL -> black
CH -> white
+
-> brown
2. Connect the first motion detector to the door
controller (Figure 4, Pos. 1).
3. Switch on the door controller and test the
operational readiness of the motion detector
according toTable 2.
FEIG ELECTRONIC GmbH
Comissioning
Figure 2: Bus connection
Figure 3: Terminal X28B
Figure 4: Connecting to the door controller
36/74
MWD BPC-H / MWD BPC-HU
blue
black
white
brown
MWD_BPC-H-HU_ver4_Manual_rev0_mul

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mwd bpc-hu

Table des Matières