OPERATION
A.
Fill the water cup with demine-
ralised or distilled water until the limit
line. Do not pour essence oils or aromatic
herbs inside the water tank.
B.
Connect the machine to electricity
and turn on the power switch.
C.
After about 6-8 minutes, water
steam begins to come out from the spray
nozzle.
D.
Press the OZONE switch and ioni-
zed steam will be coming out.
E.
Before pointing the steam towards
the patient's face, please check that the
steam is coming out properly.
F.
The security distance to be res-
pected between the patient and the
steamer arm is 30-35 cm.
G.
The temperature of the steam rea-
ches between 35 and 40 ºC.
H.
The machine is equipped with a
timer. You can program the duration and
the machine will automatically stop once
the time is over.
EFFECTS
• Thanks to the ozone function: bacteri-
cidal, disinfecting and oxygenating.
• Thanks to the heat: moisturising and
vasodilator.
• Relaxing action
• Heat dilates the pores size which helps
extracting blackheads.
CONTRAINDICATION
• It is not recommended for skins sen-
sitive to heat, to red patches or to con-
gestion. The ozone gas is a bit irritating
for the sensitive skin. The spraying is not
recommended either for asthmatic or
claustrophobic people.
WARNING
EN
Before using the steamer with a
patient, please make two complete cir-
cuits in order to check the operation. It is
also recommended to make a couple of
circuits more with some drops of vinegar
into the water in order to clean all the
internal tubes.
You should also clean the water
tank before using it for the first time.
Never point the nozzle directly
towards the patient's face without res-
pecting the security distance. Let the
steam come out before using it with the
patient to assure it comes out correctly.
Do not use the machine in wet or
non-ventilated places.
Do not use the steamer outdoor.
Do not try to open the main unit
without the supplier help or instructions.
If the power cord is damaged,
please ask the supplier to give you a new
one. Do not use the machine.
Do not leave the machine working
without water. This will extinguish the
guarantee.
Do not pour chemical products or
oils inside the water tank. This can cau-
se the steamer to pour water instead of
steam.
After operation, empty the water
tank and clean it. Once per week the tank
should be cleaned with vinegar.
Adjust the time of the treatment
according to the patient's skin.
MAINTENANCE
The lime can gather inside the
machine according to the hardness of
the water in some regions. So, attention,
always use demineralised or distilled
water.
In any case you also need to regu-
larly maintain the machine as the lime
accumulation can lead to a malfunction
of the machine, so please fill the tank
with water and some vinegar and make
a couple of complete cleaning circuits to
clean the inside.