Teuco VASCHE Manuel D'utilisation page 35

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 38
Ultrasound head diagnostics
SONIC icon
Only in the case of a Hydrosonic system, the
settings menu includes an additional icon (SONIC)
to access a page that sums up the status of
the three checks carried out on the individual
ultrasound emitting heads:
1. Frequency Check (F)
2. Cover presence check (C)
3. Current check (I)
The boxes represent the anomaly bits. When they
are lit, this indicates the presence of an anomaly.
The pictured example shows the case of a system
with only 6 heads installed. The Frequency and
Cover anomalies related to heads 7 and 8 are
active.
n.B.: Faults are only displayed if the
hydrosonic treatment is under way.
nB: The failure of one or more emitting heads
do not affect the operation of the remaining.
F
C
F
C
8 6 4 2
8 6 4 2
7 5 3 1
7 5 3 1
The numbers shown correspond to the numbering
on the wires supplying the heads.
EN
I
I
8 6 4 2
7 5 3 1
35

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Touch oled

Table des Matières