eng
If one only operates with one collar, the free side of the T-distributor has to be
closed by the closing nut. If a 3. or further freezing points are required, additional
T-distributors (accessory) can be connected to the T-distributor.
3. Operation
Augenschutz benutzen
WARNUNG
WARNUNG
CO
displaces air! Do not use ROLLER'S Polar in submerged rooms (pits,
displaces air! Do not use ROLLER'S Polar in submerged rooms (pits,
2
2
2
shafts, basements). Danger of suffocation!
The water (or other liquid) in the pipe can only be frozen when it is no longer
fl owing. All pumps must therefore be stopped and no liquid removed or allowed
to escape from the pipe. Before freezing, let the water cool down to room
temperature.
Fully open the cylinder valve. The amount of CO
matically. The liquid CO
temperature of –79°C and freezes the water within the pipe. After a brief period,
frost will form on the pipe in the vicinity of the freeze collars. If frost does not
form in accordance with time given in the table, then this indicates that the
liquid within the pipe is still fl owing (check that all pumps have been switched
off and prevent any removal or outfl ow of water) or the water is too warm. While
work is in progress, the fl ow of CO
CO
must fl ow out constantly between pipe and collar (pressure compensation).
must fl ow out constantly between pipe and collar (pressure compensation).
2
2
2
Always ensure a suffi cient supply of refrigerant by providing a stand-by cylinder.
The only way to determine the amount of remaining CO
If it is necessary to change the cylinder during work, it is essential that this proce-
dure should be complete within 7 minutes to prevent the ice pack from melting.
Once work is complete, close the cylinder valve and wait until the pressure in
the high-pressure hoses has returned to normal. Remove the high-pressure
hoses. Once the ice pack has completely melted,
remove the handle pieces with injector from the freeze collar and remove the
freeze collar.
5. Procedure in Case of Trouble
Fault: Frost does not form on the pipe.
Cause:
● Freezing time still too short.
● Pumps not switched off, outfl ow of water.
● CO
cylinder is empty or cylinder valve is not open.
cylinder is empty or cylinder valve is not open.
2
2
2
● Choke in cylinder connector with T-distributor is blocked up.
● Filter in front of injector nozzle blocked up.
6. Disposal
ROLLER'S Polar may not be thrown into the domestic waste at the end of use
but must be disposed of properly by law.
7. Manufacturer's Warranty
The warranty period shall be 12 months from delivery of the new product to the
fi rst user. The date of delivery shall be documented by the submission of the
original purchase documents, which must include the date of purchase and the
designation of the product. All functional defects occurring within the warranty
period, which are clearly the consequence of defects in production or materials,
will be remedied free of charge. The remedy of defects shall not extend or
renew the warranty period for the product. Damage attributable to natural wear
and tear, incorrect treatment or misuse, failure to observe the operational
instructions, unsuitable operating materials, excessive demand, use for unau-
thorized purposes, interventions by the customer or a third party or other
reasons, for which ROLLER is not responsible, shall be excluded from the
warranty
Services under the warranty may only be provided by customer service stations
authorized for this purpose by ROLLER. Complaints will only be accepted if
the product is returned to a customer service station authorized by ROLLER
without prior interference and in a fully assembled condition. Replaced products
and parts shall become the property of ROLLER.
6
required is controlled auto-
required is controlled auto-
2
2
2
expands in the injector and forms dry ice with a
2
refrigerant must be maintained, and the
refrigerant must be maintained, and the
2
2
2
is to weigh the cylinder.
is to weigh the cylinder.
2
2
2
completely melted, carefully unscrew and
4. Freezing Times
The freezing times and CO
requirements given in the table below are only to
requirements given in the table below are only to
2
2
2
be regarded as general guidelines and are valid for a water temperature of
approx. 20°C. The freezing times and refrigerant consumption values will there-
fore vary for higher temperatures. For freezing liquids in plastic pipes much
longer freezing times are generally required.
Table:
Freeze collar
Material
Freezing
size
time
⅛"/10/12 mm
steel
1 min
copper
1 min
¼"/
15 mm
steel
1 min
copper
2 min
⅜"/
18 mm
steel
2 min
copper
3 min
½"/
22 mm
steel
3 min
copper
5 min
¾"/
28 mm
steel
5 min
copper
7 min
1" /
35 mm
steel
7 min
copper
10 min
1¼"/ 42 mm
steel
11 min
copper
14 min
1½"
steel
16 min
54 mm
copper
24 min
2" /
60 mm
steel
29 min
* Does not include work time
Remedy:
● Pay attention to freezing times according table.
● Switch off pumps. Stop water removal.
● Change CO
cylinder or open cylinder valve.
2
● Clear blockage.
● Filter in front of injector nozzle blocked up. Unscrew injector nozzle, push fi lter
carefully from the back through the handle piece, clean fi lter (blow out).
The user shall be responsible for the cost of shipping and returning the product.
A list of the ROLLER-authorized customer service stations is available on the
Internet under www.albert-roller.de. For countries which are not listed, the
product must be sent to the SERVICE-CENTER, Neue Rommelshauser Strasse
4, 71332 Waiblingen, Deutschland. The legal rights of the user, in particular
the right to make claims against the seller in case of defects as well as claims
due to wilful violation of obligations and claims under the product liability law
are not restricted by this warranty.
This warranty is subject to German law with the exclusion of the confl ict of laws
rules of German International Private Law as well as with the exclusion of the
United Nations Convention on Contracts for the International Sales of Goods
(CISG). Warrantor of this world-wide valid manufacturer's warranty is Albert
Roller GmbH & Co KG, Neue Rommelshauser Straße 4, 71332 Waiblingen,
Deutschland.
8. Spare parts lists
For spare parts lists, see www.albert-rol
www.albert-rol
www.al
CO
Number of freezing
2
consumption
operations possible
per freeze collar
per 10 kg cylinder*
60 g
165
65 g
160
75 g
130
135 g
75
150 g
65
200 g
50
225 g
45
330 g
30
350 g
29
450 g
22
500 g
20
650 g
15
700 g
15
900 g
11
1050 g
10
1450 g
7
1900 g
5
bert-rol
bert-roller.de
ler.de
→ Downloads → Parts lists.
eng