4.4- Warning messages and alarms (EVO)
In the event of abnormal operation, the EVO series equipment will display an
alarm message on the 4th line of the screen, together with an acoustic
warning. The alarms shutdown the equipment until the problem is solved.
Similarly, it will display a warning also in the 4th line, but without an acoustic
signal or shutting down the equipment. In this case, the equipment can
continue operating, although you are informed that corrective action should be
taken.
4.4.1- Warnings
Message:
"LACK OF SALT"
Manual EVO v.3
Cell sensor is dirty.
No water flow
The
cell
is
incorrectly
connected.
Metal body in the cell.
Cell
is
incorrectly
connected.
Cell
is
damaged
completely worn down.
Swimming pool water with
very low salt concentration.
Causes:
Lack of salt in the water.
Incrustations or objects in
the electrolysis cell causing
excess current.
The electrolysis cell is worn.
Clean.
See maintenance.
Check the water system
Check wiring.
Turn off the equipment and
remove the metal body
from the sheets
Check the cell connection
and ensure that cables and
connection terminals are in
good condition.
or
Check the condition of the
cell electrodes, and replace
it
if
any
damage
observed.
Ensure that the water has
salt and that it is dissolved.
Action required:
Add salt to the swimming pool.
Clean the cell.
Replace the electrolysis cell with
a new one.