4.2.2- Main screen
On starting up the equipment, a screen will be displayed with the main
parameters.
-
The upper line displays the production %, the voltage of the electrolysis
cell and the water temperature consecutively.(If you do not have a
temperature probe, --- º will appear).
-
The second line displays the oxidation /reduction potential called RedOx
or ORP (Oxidation Reduction Potential) or ppm if working with a free
chlorine probe. "Man.", "Auto" or "Semi-auto" is displayed on the right.
-
Important: If you do not have a RedOx probe or a free chlorine probe,
the ORP reading displayed may be a random value. When selecting the
Manual mode (this mode is required if it is to operate without a probe),
the equipment will ask if you want to display the ORP line or to conceal
it.
-
The third line displays the pH reading as long as it is fitted in the
equipment (EVO model) and the relay status.
-
The fourth line displays the Menu (press the OK button to access the
menu) and the time on the clock. If any alarm or warning occurs, it will
also be displayed on this line.
4.2.3- Main menu
Press the "OK" button from the main screen to access the main menu.
Using the buttons you can select a line of the menu, indicated by the
arrow (). The OK button is used to confirm the selection.
Manual EVO v.3
73 / 142